Configuration Mode Commands : System Administration Commands : Alarm Commands : alarm rate-limit
  
alarm rate-limit
Sets the alarm rate-limit values.
Syntax
alarm <type> rate-limit [email | snmp] term {long | medium | short} {count <value> | window <duration-seconds>}
Parameters
<type>
See the alarm enable command for a complete listing and description of alarm types.
email
Sets rules for email.
snmp
Sets rules for SNMP.
term
Sets the alarm event rate-limit term value. Valid choices are:
•  long
•  medium
•  short
count <value>
Sets the count value. The default values are 50 (long), 20 (medium), and 5 (short).
window <duration-seconds>
Sets the duration of time, in seconds, that the window remains open. The default values are 604,800 (long), 86,400 (medium), and 3600 (short).
Usage
There are three term values—long, medium, and short. Each has a window, which is a number of seconds, and a maximum count. If, for any term value, the number of alarm events exceeds the maximum count during the window, the corresponding email/SNMP notifications are not sent.
Example
amnesiac (config) # alarm crl_error rate-limit email term short window 3500
Product
SCC, Interceptor, Mobile Controller, SteelHead CX, SteelHead EX, SteelHead-v, SteelHead-c
Related Commands
alarm clear, alarm clear-threshold, alarm enable, alarm error-threshold, show alarm, show alarms