Configuration Mode Commands : SteelHead configuration commands : steelhead communication mode-ipv6
  
steelhead communication mode-ipv6
Enables IPv6 connection forwarding between SteelHeads and SteelHead Interceptors in a cluster.
Syntax
[no] steelhead communication mode-ipv6
Parameters
None
Usage
The no option of this command disables IPv6 connection forwarding between SteelHeads and SteelHead Interceptors in a cluster.
Before using this command, these tasks are required:
Path selection must be disabled. To disable path selection, use the no path-selection enable command.
Multi-interface support must be enabled. To enable multi-interface support, use the steelhead communication multi-interface enable command or the steelhead interceptor communication multi-interface enable command.
All SteelHead neighbors must be removed. To remove a neighbor, use the no command option with the appropriate CLI command (for example, the no steelhead name or no failover steelhead addr).
Remove all appliances from the connection forwarding appliance list and the failover appliance list. To remove an appliance from these lists, use the no command option with the appropriate CLI command (for example, no interceptor name, no steelhead interceptor name, or no failover steelhead interceptor name).
Use this command on each SteelHead and each SteelHead Interceptor in the cluster.
You must restart the service for your changes to take effect.
Example
amnesiac (config) # steelhead communication mode-ipv6
Product
Interceptor, SteelHead CX, SteelHead-v, SteelHead-c
Related Commands
“steelhead communication multi-interface enable,” “steelhead interceptor communication multi-interface enable,” “steelhead interceptor communication mode-ipv6,” “steelhead name,” “failover steelhead addr,” path-selection enable