Configuration Mode Commands : SteelHead Interceptor Commands : Interceptor Peering and Redirect Commands : steelhead communication multi-interface enable
  
steelhead communication multi-interface enable
Enables the SteelHead communication multiple interface support.
Syntax
[no] steelhead communication multi-interface enable
Parameters
None
Usage
When using more than one data connection on the SteelHead, you must enable multiple interface support. If you enable multiple interface support, the following constraints apply:
•  5.0x SteelHeads must be running RiOS 5.0.7 or later.
•  5.5.x SteelHeads must be running RiOS 5.5.2 or later.
•  Load-balancing rules apply only to the main IP address.
The no command option disables multiple interface support.
This command replaces the in-path neighbor multi-interface enable command.
Example
amnesiac (config) # steelhead communication multi-interface enable
Product
Interceptor
Related Commands
show steelhead communication