Configuration Mode Commands : SteelHead Configuration Commands : Asymmetric Route Detection Commands : in-path cdp allow-failure enable
  
in-path cdp allow-failure enable
In PBR deployments with multiple in-path interfaces, this command enables Cisco Discovery Protocol (CDP) packets to be sent to the other routers when one of the routers goes down.
Syntax
[no] in-path cdp allow-failure enable
Parameters
None
Usage
With PBR, CDP is used by the SteelHead to notify the router that the SteelHead is still alive and that the router can still redirect packets to it.
In some cases, the you might want to disable this command so that if one router goes down, the SteelHead stops sending CDP packets to all the routers it is attached to and connections are redirected and optimized by another SteelHead.
This can be useful when the routers are configured to redirect to a SteelHead when all routers are up but to another SteelHead when one router goes down.
For details about how to configure a SteelHead for PBR with CDP, see the SteelHead Deployment Guide.
The no command option disables CDP.
Example
amnesiac (config) # in-path cdp allow-failure enable
Product
SteelHead CX, SteelHead EX, SteelHead-v, SteelHead-c
Related Commands
show in-path cdp