Configuration Mode Commands : SteelHead Configuration Commands : Asymmetric Route Detection Commands : in-path asymmetric routing pass-through enable
  
in-path asymmetric routing pass-through enable
Enables the pass-through feature for asymmetric routing.
Syntax
[no] in-path asymmetric routing pass-through enable
Parameters
None
Usage
Use this command to ensure connections are not passed-through the SteelHeads unoptimized. Logging occurs when asymmetric routes are detected. If disabled, asymmetrically routed TCP connections are still detected and a warning message is logged, but the connection is not passed-through and no alarm or email is sent.
If the system detects asymmetric routing, the pair of IP addresses, defined by the client and server addresses of the connection, is cached in the asymmetric routing cache on the SteelHead. Further connections between these hosts are not optimized until that particular asymmetric routing cache entry times out.
The no command option disables asymmetric routing pass through.
Example
amnesiac (config) # no in-path asymmetric routing pass-through enable
Product
SteelHead CX, SteelHead EX, SteelHead-v, SteelHead-c
Related Commands
show in-path asym-route-tab