Installing Edge Appliances : Reinstalling Edge appliances
  
Reinstalling Edge appliances
In case of accidental removal, partial deletion or any other major issues that are not recoverable with the Edge VM, the Edge can be reinstalled on the same target server and this requires complete clean up of existing Edge VM and formatting the datastore associated with the Edge VM. Then the edge VM can be reinstalled.
Edge VMs To Install
===================
6c:92:cf:31:94:30_192.168.1.12
 
6c:92:cf:31:8f:90_192.168.1.18
 
Found appliance(s) to install. Press I to install from the current list, [Enter] to Rescan for latest installation status, or Q to quit: i
 
Enter the appliance to install [0,1,2,..]
 
0 -> 6c:92:cf:31:94:30_192.168.1.12
 
1 -> 6c:92:cf:31:8f:90_192.168.1.18
 
Select the appliance number with the MAC/IP Edge already deployed and wish to proceed for Options for Re-install the appliance.
Enter the number : 1
 
Options:
 
1. Re-install the appliance (Requires deleting VM and formatting datastore).
 
2. Multiple deployments (Keeps the existing VM).
 
Enter your choice [1 for Re-install / 2 for Multiple Deployments]: 1
 
Re-installing 6c:92:cf:31:8f:90_192.168.1.18.
 
Please ensure the VM is deleted and the respective datastore is formatted before proceeding.
 
Do you want to continue [n (for No) / y (for Yes) / r (for Rescan)]: y
 
Note: Ensure to Select the Datastore that is formatted and clean.
 
After a successful installation, the installer output lists the target appliances that are successfully installed.
 
 
Successful Installations
========================
6c:92:cf:31:8f:90_192.168.1.18 | Start Time: Thu Feb 06 2025 06:29:33 | SRSE1105 | CPUs: 6 | RAM: 49152 | Size: 5765 GB | End Time: Thu Feb 06 2025 06:31:41
 
Failed Installations
====================
[INFO] No failed appliance history in the installer.