CX xx70 Appliance Specifications
  
CX xx70 Appliance Specifications
This appendix describes the ports, LEDs, and the technical and environmental specifications for the xx70 appliances.
CX 3070 specifications
This section describes the ports, LEDs, and technical and environmental specifications.
Port location and LEDs
These figures illustrate the port locations, LEDs, and buttons.
CX 3070 front panel with LEDs and buttons
CX 3070 back panel
By default, the SteelHead CX 3070 ships with a bypass card in slot 3. The default interface names are LAN3_0, WAN3_0, LAN3_1, and WAN3_1. This appliance doesn’t have an inpath0_0 interface as found on earlier appliances and by default the CX 3070 uses inpath3_0 and inpath3_1.
This table summarizes the appliance LEDs and buttons.
Reference
LED/button
Description
1
System ID Button with Integrated LED
Maintenance = Blue
Toggles the integrated ID LED and the blue server board ID LED on and off. The System ID LED identifies the system for maintenance when installed in a rack of similar server systems. You can also remotely turn on and turn off the System ID LED using the IPMI “Chassis Identify” command which causes the LED to blink for 15 seconds.
A duplicate System ID LED is on the back of the appliance to the left of the video port.
2
NMI Button
Pressing the NMI button puts the appliance in a halt state and issues a non-maskable interrupt (NMI). This helps when performing diagnostics for a given issue where a memory download is necessary to determine the cause of the problem. To prevent an inadvertent system halt, the NMI button is located behind the Front Control Panel faceplate and is only accessible with the use of a small tipped tool such as a pin or paper clip.


3
10
Network Activity LED

Primary
Auxiliary
Link = Green
Activity = Blinks green. The blink rate is consistent with the amount of network activity.
The appliance doesn’t use the LEDs 4 and 9 shown in Figure: CX 5070 and CX 7070 front panel with LEDs and buttons.
5
System Cold Reset Button
Pressing this button reboots the appliance.
6
System Status LED
The System Status LED shows the current health of the server system.
Healthy = Green
Degraded = Yellow
Critical = Blinks Yellow
A duplicate System ID LED is on the back of the appliance to the right of the AUX port.
7
Power Button with Integrated LED
System On = Green
System Off = No light
8
Drive Activity
Activity = Blinks green
 
LEDs on Disk Drives
Activity LED
Read/Write Activity = Blinks green
Disk Fault LED
Failed Disk = Orange
RAID Rebuild = Blinks Orange
 
LEDs on Primary and AUX Ports
Left LED
Link = Green
Activity = Blinks green
Right LED
10 Mbps data rate = No light (with link on left LED)
100 Mbps data rate = Green
1000 Mbps data rate = Yellow
 
LEDs on Default 4 Port Copper Bypass Card
Link/Activity LED
Link = Green
Activity = Blinks green
Speed/Bypass/Disconnect LED
1000 Mbps = Yellow
100 Mbps = Green
10 Mbps = Off
Bypass = Blinks green
Disconnect = Blinks Yellow
 
LEDs on Power Supply
Power on and healthy = Green
Power Off = Off
Standby = Blinks green
Power lost but second power supply has power = Amber
Power on with warning events (high temperature, high power, high current, slow fan) = Blinks amber
Technical Specifications
This table summarizes the technical specifications for the systems.
 
CX 3070-L/M/H
Form factor
1U
Hard disk
2 x 1000 GB, 2 SSD x 160
Data store
320 GB SSD
Dimensions (LxWxH)
25.21 x 17.24 x 1.7 in
640.4 x 438 x 43.2 mm
Weight (without packaging)
27 lb / 12.2 kg
Voltage frequency
100–127V, 200–240 V
PSU
2 x 450 W
100–127VAC/8A, 50/60 Hz
200–240 VAC/4A, 50/60 Hz
PCI slots
3
Included bypass ports/max # ports
4/12
Power requirements and consumption
This table summarizes the power specifications for the systems. The systems are rated at the following power characteristics when operating at nominal AC input voltages (120 V and 230 V).
System
CX 3070
CX 3070
Configuration
All (L/M/H)
All (L/M/H)
PSU type
2 x 450 W
2 x 450 W
AC input
120 V
230 V
Max. amps.
1.54
.76
Max. watts
152.8
145.4
Typical watts
122
116
Max VA
154
147
Power factor
98.96
99.16
BTU (typical)
417
397
Environmental specifications
This table summarizes the environmental requirements for the systems.
Specification
Description
Operating acoustic
7.0 BA sound power (Typical)
52 dBa sound pressure
Temperature (operating)
10° to 35°C
50° to 95 F
Temperature (storage)
-40° to 70°C
-40° to 158°F
Relative humidity
50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures from 25° to 35°C)
CX 5070 and CX 7070 specifications
This section describes the ports, LEDs, and technical and environmental specifications.
Port location and LEDs
These figures illustrate the port locations and LEDs.
CX 5070 and CX 7070 front panel with LEDs and buttons
Disks 0 and 23 are HDD. Disks 1 through 22 are SSD.
CX 5070 and CX 7070 back panel
By default, the SteelHead CX 5070 and CX 7070 ship with a bypass card in slot 1. The default interface names are LAN1_0, WAN1_0, LAN1_1, and WAN1_1. This appliance doesn’t have an inpath0_0 interface as found on earlier appliances and by default the CX 5070 and CX 7070 use inpath1_0 and inpath1_1.
This table summarizes the appliance LEDs and buttons.
Reference
LED/button
Description
1
System ID Button with Integrated LED
Maintenance = Blue
Toggles the integrated ID LED and the blue server board ID LED on and off. The System ID LED identifies the system for maintenance when installed in a rack of similar server systems. You can also remotely turn on and turn off the System ID LED using the IPMI “Chassis Identify” command which causes the LED to blink for 15 seconds.
A duplicate System ID LED is on the back of the appliance to the left of the video port.
2
NMI Button
Pressing the NMI button puts the appliance in a halt state and issues a non-maskable interrupt (NMI). This helps when performing diagnostics for a given issue where a memory download is necessary to determine the cause of the problem. To prevent an inadvertent system halt, the NMI button is located behind the Front Control Panel faceplate and is only accessible with the use of a small tipped tool such as a pin or paper clip.


3
10
Network Activity LED

Primary
Auxiliary
Link = Green
Activity = Blinks green. The blink rate is consistent with the amount of network activity.
The appliance doesn’t use the LEDs 4 and 9 shown in Figure: CX 5070 and CX 7070 front panel with LEDs and buttons.
5
System Cold Reset Button
Pressing this button reboots the appliance.
6
System Status LED
The System Status LED shows the current health of the server system.
Healthy = Green
Degraded = Yellow
Critical = Blinks Yellow
7
Power Button with Integrated LED
System On = Green
System Off = No light
8
Drive Activity
Activity = Blinks green
 
LEDs on Disk Drives
Activity LED
Read/Write Activity = Blinks green
Disk Fault LED
Failed Disk = Orange
RAID Rebuild = Blinks Orange
 
LEDs on Primary and AUX Ports
 
Left LED
Link = Green
Activity = Blinks green
Right LED
10 Mbps data rate = No light (with link on left LED)
100 Mbps data rate = Green
1000 Mbps data rate = Yellow
 
LEDs on Default 4 Port Copper Bypass Card
 
Link/Activity LED
Link = Green
Activity = Blinks green
Speed/Bypass/Disconnect LED
1000 Mbps = Yellow
100 Mbps = Green
10 Mbps = Off
Bypass = Blinks green
Disconnect = Blinks Yellow
 
LEDs on Power Supply
 
Power on and healthy = Green
Power Off = Off
Standby = Blinks green
Power lost but second power supply has power = Amber
Power on with warning events (high temperature, high power, high current, slow fan) = Blinks amber
Technical specifications
This table summarizes the technical specifications for the systems.
 
CX 5070-M/H
CX 7070-L
CX 7070-M
CX 7070-H
Form factor
2 U
2 U
2 U
2 U
Hard disk/SSD
2 x 1000 GB HDD
6 x 160GB SSDs
2 x 1000 GB HDD
6 x 300 GB SSDs
2 x 1000 GB HDD
8 x 300 GB SSD
2 x 1000 GB HDD
16 x 300 GB SSD
Data Store
960 GB SSD
1.8 TB SSD
2.4 TB SSD
4.8 TB SSD
Dimensions (LxWxH)
27.87 x 17.24 x 3.45 in
707.8 x 438 x 87.6 mm
27.87 x 17.24 x 3.45 in
707.8 x 438 x 87.6 mm
27.87 x 17.24 x 3.45 in
707.8 x 438 x 87.6 mm
27.87 x 17.24 x 3.45 in
707.8 x 438 x 87.6 mm
Weight (without packaging)
41 lb/18.6 kg
41 lb/18.6 kg
41 lb/18.6 kg
42 lb/19.05 kg
Voltage frequency
100–127 V, 200–240 V
100–127 V, 200–240 V
100–127 V, 200–240 V
100–127 V, 200–240 V
PSU
 
2 x
770 W
100–127 VAC/8.2 A, 50/60 Hz
200–240 VAC/4.4 A, 50/60 Hz
2 x
770 W
100–127 VAC/8.2 A, 50/60 Hz
200–240 VAC/4.4 A, 50/60 Hz
2 x
770 W
100–127 VAC/8.2 A, 50/60 Hz
200–240 VAC/4.4 A, 50/60 Hz
2 x
770 W
100–127 VAC/8.2 A,
50/60 Hz
200–240 VAC/4.4 A,
50/60 Hz
PCI slots
6
6
6
6
Included bypass ports/max # ports
4/20
4/20
4/20
4/20
Power requirements and consumption
This table summarizes the power specifications for the systems. The systems are rated at the following power characteristics when operating at nominal AC input voltages (120 V and 230 V).
System
CX 5070
CX 7070
Configuration
All (M/H)
All (L/M/H)
PSU type
2 x 770 W
2 x 770 W
AC input
120 V
230 V
120 V
230 V
Max. amps.
3.0
1.5
5.3
2.7
Max. watts
298
291
527
520
Typical watts
238
232
422
416
Max VA
301
293
533
524
Power factor
98.96
99.16
98.96
99.16
BTU (typical)
814
794
1439
1418
Environmental specifications
This table summarizes the environmental requirements for the systems.
 
CX 5070
CX 7070
Operating acoustic
7.0 BA sound power (Typical)
55 dBa sound pressure
7.0 BA sound power (Typical)
55 dBa sound pressure
Temperature (operating)
10° to 35°C
50° to 95 F
10° to 35°C
50° to 95 F
Temperature (storage)
-40° to 70°C
-40° to 158°F
-40° to 70°C
-40° to 158°F
Relative humidity
50% to 90%, noncondensing with a maximum wet bulb of 28°C (at temperatures from 25° to 35°C)
50% to 90%, noncondensing with a maximum wet bulb of 28°C (at temperatures from 25° to 35°C)