Label | Control panel descriptions | Description |
1 | USB port | |
2 | NMI Button | Puts the appliance in a halt state and issues a non-maskable interrupt (NMI). This helps when performing diagnostics for a given issue where a memory download is necessary to determine the cause of the problem. To prevent an inadvertent system halt, the NMI button is located behind the front Control Panel faceplate and is only accessible with the use of a small tipped tool such as a pin or paper clip. |
3 | Primary Network Interface Card (NIC) activity LED | Solid green = Network link is detected. Blinks green = Activity. The blink rate is consistent with the amount of network activity. |
4 | System Cold Reset Button | Reboots the appliance. |
5 | Hardware Status LED | Off = System is powered off. Solid green = Hardware is working correctly. Blinks green= System hardware is degraded. The system is operating in a degraded state although still functional, or system is operating in a redundant state but with an impending failure warning. The Hardware Status LED does not detect software issues, such as licensing status or the system becoming unresponsive. Only hardware status is shown. Blinks amber = The system is operating in a degraded state with an impending failure warning. Solid amber = The system has failed or shutdown. |
6 | Power Button with Integrated LED | Green = System on No light = System off |
7 | Drive Activity | Blinks green = Activity |
8 | Auxiliary NIC activity LED | Solid green = Network link is detected. Blinks green = Activity. The blink rate is consistent with the amount of network activity. |
9 | System ID Button with Integrated LED | Toggles the integrated ID LED and the blue server board ID LED on and off. The System ID LED identifies the system for maintenance when installed in a rack of similar server systems. You can also remotely turn on and turn off the System ID LED using the IPMI “Chassis Identify” command which causes the LED to blink for 15 seconds. |
LEDs on Disk Drives | Activity LED Blinks green = Read/write activity Disk Fault LED Orange = Failed disk Blinks Orange = RAID rebuild |
Specification | Description |
Primary and AUX Ports | Left LED Solid green = Network link is detected. Blinks green = Activity Right LED No light (with link on left LED) = 10 Mbps data rate Green = 100 Mbps data rate Yellow = 1000 Mbps data rate |
LEDs on Power Supply | Solid green = Power on and healthy No AC power = Off Blinks green = Standby or power supply firmware updating Amber = Power lost but second power supply has power Blinks amber = Power on with warning events (high temperature, high power, high current, slow fan) |
Specification | Description |
Form factor | 2U |
Hard disk/SSD | 10 Hot swappable drives |
Data store | 9.6 TB |
Packaged dimensions (LxWxH) | 37 x 24 x 11 in. 939.8 x 609.6 x 279.4 mm |
Weight (without packaging) | 46 lb, 20.87 kg |
Voltage frequency | 100-127 V, 200-240 V |
PSU | 2 x 1100 W 100-127 VAC/10 A, 50/60 Hz 200-240 VAC/6 A, 50/60 Hz |
PCI slots | 6 |
Maximum number of ports | 8 |
Specification | Description |
PSU type | 2 x 1100 W |
AC input | 230 V |
Max. amps. | 2.7 |
Max. watts | 546 |
Typical watts | 437 |
Max VA | 575 |
Power factor | 99.16 |
BTU (typical) | 1490 |
Specification | Description |
Operating acoustic | 70 Decibels |
Temperature (Operating) | 10° to 35°C (50° to 95°F) |
Temperature (Storage) | -40° to 70°C (-40° to 158°F) |
Relative humidity (operating) | 20% to 80%, noncondensing with a maximum wet bulb of 28°C (at temperatures from 25° to 35°C) |