LED | Description | |
Power On/Power Button | The power-on indicator lights when the system power is on. When the system bezel is installed, the power button isn’t accessible. | |
HDD | Lights when the hard disk drive (HDD) is in use. | |
System Diagnostics (4) | ![]() | The system is in a normal off condition or a possible pre-BIOS failure has occurred. Plug the system into a working electrical outlet and press the power button. The diagnostic lights aren’t lit after the system successfully boots to the operating system. The system is in a normal operating condition after POST. |
![]() | ||
![]() | Possible processor failure. Contact Riverbed Support at https://support.riverbed.com. | |
![]() | ||
![]() | Possible NIC card failure. Contact Riverbed Support at https://support.riverbed.com. | |
![]() | Possible video failure. Contact Riverbed Support at https://support.riverbed.com. | |
![]() | ||
![]() | ||
![]() | ||
System Status | (On both the front and back panels) Lights blue when the system hardware is operating normally. Lights orange when the system needs attention due to a problem. To determine the current status of the Management Console software, check the Management Console status bar. | |
System ID Button | (On both the front and back panels) Enables you to locate a system within a rack. When you push either of the buttons, the system status indicators on the front and back panels light blue until you push one of the buttons again. | |
SSD | Lights when the solid state drive (SSD) is in use. | |
LAN-WAN Ports | Link/Activity | Green = LAN or WAN link is up. Blinks green = LAN or WAN link is active. |
Disconnect | Green = LAN or WAN link is in disconnect mode. | |
Bypass | Green = LAN or WAN link is in bypass mode. |
EX560 G/L/M/H | EX760 L/M/H | |
Form Factor | 1U | 1U |
HDD / SSD | 1 TB HDD 1 x8 0 GB SSD | 1 TB HDD 1 x 160 GB SSD |
Data Store | 40-70 GB 380 GB VSP | 140 GB 380 GB VSP |
Dimensions (LxWxH) | 17.09 x 15.52 x 1.66 in (434.0 x 394.3 x 42.4 mm) | 17.09 x 15.52 x 1.66 in (434.0 x 394.3 x 42.4 mm) |
Weight (without packaging) | 17.76 lbs (8.058 kg) | 17.76 lbs (8.058 kg) |
PCIe Slots | 0 | 0 |
Onboard Bypass Ports/Max # Ports | 4/4 | 4/4 |
System | EX560/760 | EX560/760 |
Configuration | All (G/L/M/H) | All (G/L/M/H) |
PSU Type | 1x250W 100-240Vac, 50/60Hz, 2-1 A | 1x250W |
AC Input | 120V (100-127VAC) | 230V (200-240VAC) |
Max. Amps. | 1.2 | 0.6 |
Max. Watts | 135 | 135 |
Typical Watts | 85 | 80 |
Max VA | 140 | 140 |
Power Factor | 97 | 97 |
Heat Dissipation in BTU/hour (Typical) | 295 | 280 |
EX560, EX760 | |
Operating Acoustic | 50 dBA Sound pressure (Typical) |
Temperature (Operating) | 10º - 40ºC 50° - 104ºF |
Temperature (Storage) | -40º - 65ºC -40º - 149ºF |
Relative Humidity | 20% - 80% noncondensing |
Storage Humidity | 5% - 95% noncondensing |
Operating Altitude | -50 ft - 10,000 ft (-15.24 m - 3048 m) |
LED | Status |
SYSTEM | Normal = Blue System Boot = Red |
PRI = Primary AUX = Auxiliary REM = Remote | Link and Traffic = Blinks Blue |
LAN-WAN | Link and Traffic = Blinks Blue |
BYP/BLK BYP = Bypass BLK = Block (Disconnect) | Normal = No Light Bypass or Block (Disconnect) = Orange |
HDDs/SSDs | Disk Connected = Blue Read/Write Activity = Blinks Blue Failed Disk = Orange |
Back Panel PRI = Primary AUX = Auxiliary REM = Remote | Left LED Link = Green Activity = Blinks Green Right LED GB = Orange 100 MB = Green (REM only at 100 MB) 10 MB = No Light |
Back Panel LAN-WAN | Left LED Link = Green Activity = Blinks Green Right LED GB = Orange 100 MB = Green 10 MB = No Light BYP/BLK Normal = No Light Bypass or Block (Disconnect) = Orange |
EX1160 G/L/M/H | EX1160 VH | |
Form Factor | 1U | 1 U |
HDD / SSD | 2 x 1 TB HDD 2 x 80 GB SSD | 2 x 1 TB HDD 2 x 160 GB SSD |
Data Store | 140 GB SSD 415 GB VSP | 280 GB SSD 415 GB VSP |
Dimensions (LxWxH) | 25.4 x 17.2x1.71 in (645.4 x 436x43.5 mm) | 25.4 x 17.2x1.71 in (645.4 x 436 x 43.5 mm) |
Weight (without packaging) | 36 lbs (16.36 kg) | 36 lbs (16.36 kg) |
PCIe Slots | 2 | 2 |
Onboard Bypass Ports/Max # Ports | 4/8 | 4/8 |
System | EX1160 | EX1160 |
Configuration | All (G/L/M/H/VH) | All (G/L/M/H/VH) |
PSU Type | 2 x 450 W 100 - 127 Vac 8A, 50/60 Hz | 2 x 450 W 200 -2 40 Vac 4A, 50/60 Hz |
AC Input | 120 V (100 - 127 VAC) | 230 V (200 - 240 VAC) |
Max. Amps. | 4.1 | 3.4 |
Max. Watts | 220 | 220 |
Typical Watts | 175 | 180 |
Max VA | 225 | 265 |
Power Factor | 97 | 92 |
Heat Dissipation in BTU/hour (Typical) | 605 | 610 |
EX1160 | |
Operating Acoustic | 61.5 dBA Sound pressure (Typical) |
Temperature (Operating) | 10º - 40ºC 50° - 104ºF |
Temperature (Storage) | -40º - 65ºC -40º - 149ºF |
Relative Humidity | 20% - 80% noncondensing |
Storage Humidity | 5% - 95% noncondensing |
Operating Altitude | -50 ft - 10,000 ft (-15.24 m - 3048 m) |
LED | Status |
SYSTEM | Normal = Blue System Boot = Red |
PRI = Primary AUX = Auxiliary REM = Remote | Link and Traffic = Blinks Blue |
LAN-WAN | Link and Traffic = Blinks Blue |
BYP/BLK BYP = Bypass BLK = Block (Disconnect) | Normal = No Light Bypass or Block (Disconnect) = Orange |
HDDs/SSDs | Disk Connected = Blue Read/Write Activity = Blinks Blue Failed Disk = Orange |
Back Panel PRI = Primary AUX = Auxiliary REM = Remote | Left LED Link = Green Activity = Blinks Green Right LED GB = Orange 100 MB = Green (REM only at 100 MB) 10 MB = No Light |
Back Panel LAN-WAN | Left LED Link = Green Activity = Blinks Green Right LED GB = Orange 100 MB = Green 10 MB = No Light BYP/BLK Normal = No Light Bypass or Block (Disconnect) = Orange |
EX1260-2 G/L/M/H | EX1260-2 VH | EX1260-4 G/L/M/H | EX1260-4 VH | |
Form Factor | 2U | 2U | 2U | 2U |
HDD / SSD | 4 x1 TB HDD 2 x 8 0 GB SSD | 4 x 1 TB HDD 4 x 80 GB SSD | 8 x 1 TB HDD 2 x 80 GB SSDs | 8 x1 TB HDD 4 x 80 GB SSD |
Data Store | 140 GB 860 GB VSP | 280 GB 860 GB VSP | 140 GB 1850 GB VSP | 280 GB 1850 GB VSP |
Dimensions (LxWxH) | 25.4 x 17.2 x 3.43 in (645.4 x 436 x 87.1 mm) | 25.4 x17.2 x 3.43 in (645.4 x 436 x 87.1 mm) | 25.4 x 17.2 x 3.43 in (645.4 x 436 x 87.1 mm) | 25.4 x 17.2 x 3.43 in (645.4 x 436 x 87.1 mm) |
Weight (without packaging) | 58 lbs (23.36 kg) | 58 lbs (23.36 kg) | 58 lbs (23.36 kg) | 58 lbs (23.36 kg) |
PCIe Slots | 4 | 4 | 4 | 4 |
Onboard Bypass Ports/Max # Ports | 4/8 | 4/8 | 4/8 | 4/8 |
System | EX1260 (2TB) | EX1260 (2TB) | EX1260 (4TB) | EX1260 (4TB) |
Configuration | All (G, L, M, H, VH) | All (G, L, M, H, VH) | All (G, L, M, H, VH) | All (G, L, M, H, VH) |
PSU Type | 2 x 770W 100 - 127Vac 8A, 50/60Hz | 2 x 770W 200 - 240Vac 4A, 50/60Hz | 2 x 770W 100 -1 27Vac 8A, 50/60Hz | 2 x 770W 200 - 240Vac 4A, 50/60Hz |
AC Input | 120V (100-127VAC) | 230V (200-240VAC) | 120V (100-127VAC) | 230V (200-240VAC) |
Max. Amps. | 4.5 | 2.1 | 5.2 | 3.2 |
Max. Watts | 419 | 400 | 445 | 430 |
Typical Watts | 330 | 320 | 335 | 345 |
Max VA | 419 | 490 | 445 | 515 |
Power Factor | 98 | 94 | 97 | 94 |
Heat Dissipation in BTU/hour (Typical) | 1130 | 1190 | 1726 | 1175 |
EX1260 | |
Operating Acoustic | 65.5 dBA Sound pressure (Typical) |
Temperature (Operating) | 10º - 40ºC 50° - 104ºF |
Temperature (Storage) | -40º - 65ºC -40º - 149ºF |
Relative Humidity | 20% - 80% noncondensing |
Storage Humidity | 5% - 95% noncondensing |
Operating Altitude | -50 ft - 10,000 ft -15.24 m - 3048 m |
LED | Status |
SYSTEM | Normal = Blue System Boot = Yellow |
PRI = Primary AUX = Auxiliary REM = Remote | Link and Traffic = Blinks Blue |
LAN-WAN | Link and Traffic = Blinks Blue |
BYP/BLK BYP = Bypass BLK = Block (Disconnect) | Normal = No Light Bypass or Block (Disconnect) = Orange |
HDDs/SSDs | Activity LED Disk Connected = Blue Read/Write Activity = Blinks Blue Disk Fault LED Failed Disk = Orange |
Back Panel PRI = Primary AUX = Auxiliary REM = Remote | Left LED Link = Green Activity = Blinks Green Right LED GB = Orange 100 MB = Green (REM only at 100 MB) 10 MB = No Light |
Back Panel LAN-WAN | Left LED Link = Green Activity = Blinks Green Right LED GB = Orange 100 MB = Green 10 MB = No Light BYP/BLK Normal = No Light Bypass or Block (Disconnect) = Orange |
EX1360 G/L/M | EX1360P G/L/M | |
Form Factor | 2U | 2U |
HDD / SSD | 20 x 1 TB HDD 4 x 100 GB SSD | 20 x 1 TB HDD 4 x 400 GB SSD |
Data Store | 320 GB 4000 GB VSP | 320 GB 4000 GB VSP |
Dimensions (LxWxH) | 25.4 x 17.2 x 3.43 in (645.4 x 436 x 87.1 mm) | 25.4 x 17.2 x 3.43 in (645.4 x 436 x 87.1 mm) |
Weight (without packaging) | 58 lbs (23.36 kg) | 58 lbs (23.36 kg) |
PCIe Slots | 4 | 4 |
Onboard Bypass Ports/Max # Ports | 4/8 | 4/8 |
System | EX1360 | EX1360 |
Configuration | All (G, L, M) | All (G, L, M) |
PSU Type | 2 x 770W 100 - 127Vac 8A, 50/60Hz | 2 x 770W 200 - 240Vac 4A, 50/60Hz |
AC Input | 120V (100 - 127VAC) | 230V (200 - 240VAC) |
Max. Amps. | 6.4 | 3.3 |
Max. Watts | 635 | 630 |
Typical Watts | 505 | 500 |
Max VA | 650 | 464590 |
Power Factor | 98 | 97 |
Heat Dissipation in BTU/hour (Typical) | 1726 | 1712 |
EX1360 | |
Operating Acoustic | 65.5 dBA Sound pressure (Typical) |
Temperature (Operating) | 10º - 40ºC 50° - 104ºF |
Temperature (Storage) | -40º - 65ºC -40º - 149ºF |
Relative Humidity | 20% - 80% noncondensing |
Storage Humidity | 5% - 95% noncondensing |
Operating Altitude | -50 ft - 10,000 ft (-15.24 m - 3048 m) |
Series | Part number | Minimum CPU | Allocation RiOS / VSP | HDD/SSD | RAM, shipped | RAM, available to VSP/ESXi |
EX560 All versions | EXA-00560-B010 | 1 x 4 cores 3.1 GHz | 2 cores / 2 cores | 1 TB HDD 1 x 80 GB SSD | 8 GB (16 GB with SteelFusion-licensed model) | 4 GB (9 GB) |
EX760 All versions | EXA-00760-B010 | 1 x 4 cores 3.1 GHz | 2 cores/ 2 cores | 1 TB HDD 1 x 160 GB SSD | 16 GB | 8 GB |
EX1160 G/L/M/H versions | EXA-01160-B030 | 2 x 4 cores 2.2 GHz | 1 x 4 cores / 1x 4 cores | 2 x 1 TB HDD 2 x 80 GB SSD | 20 GB | 10 GB |
EX1160 G/L/M/H versions | EXA-01160-B035 | 2 x 4 cores 2.2 GHz | 1 x 4 cores / 1x 4 cores | 2 x 1 TB HDD 2 x 80 GB SSD | 48 GB | 32 GB |
EX1160 VH version | EXA-01160-B020 | 2 x 4 cores 2.2 GHz | 1 x 4 cores / 1x 4 cores | 2 x 1 TB HDD 2 x 160 GB SSD | 24 GB | 12 GB |
EX1160 VH version | EXA-01160-B025 | 2 x 4 cores 2.2 GHz | 1 x 4 cores / 1x 4 cores | 2 x 1 TB HDD 2 x 160 GB SSD | 48 GB | 32 GB |
EX1260-2 G/L/M/H versions | EXA-01260-B010 (EXA-01260-B020) | 2 x 6 cores 2.6 GHz | 1 x 6 cores / 1 x 6 cores | 4 x 1 TB HDD 2 x 80 GB SSD | 24 GB (upgradeable to 32 GB) | 11 GB (upgradeable to 19 GB) |
EX1260-2 G/L/M/H versions | EXA-01260-B025 | 2 x 6 cores 2.6 GHz | 1 x 6 cores / 1 x 6 cores | 4 x 1 TB HDD 2 x 80 GB SSD | 72 GB | 48 GB |
EX1260-2 VH version | EXA-01260-B030 (EXA-01260-B040) | 2 x 6 cores 2.6 GHz | 1 x 6 cores / 1 x 6 cores | 4 x 1 TB HDD 4 x 80 GB SSD | 24 GB (upgradeable to 32 GB) | 7 GB (upgradeable to 15 GB) |
EX1260-2 VH version | EXA-01260-B045 | 2 x 6 cores 2.6 GHz | 1 x 6 cores / 1 x 6 cores | 4 x 1 TB HDD 4 x 80 GB SSD | 72 GB | 48 GB |
EX1260-4 G/L/M/H versions | EXA-01260-B050 (EXA-01260-B060) | 2 x 6 cores 2.6 GHz | 1 x 6 cores / 1 x 6 cores | 4 x 1 TB HDD 2 x 80 GB SSD | 32 GB (upgradeable to 64 GB) | 14 GB (upgradeable to 45 GB) |
EX1260-4 G/L/M/H versions | EXA-01260-B065 | 2 x 6 cores 2.6 GHz | 1 x 6 cores / 1 x 6 cores | 4 x 1 TB HDD 2 x 80 GB SSD | 88 GB | 64 GB |
EX1260-4 VH version | EXA-01260-B070 (EXA-01260-B060) | 2 x 6 cores 2.6 GHz | 1 x 6 cores / 1 x 6 cores | 4 x 1 TB HDD 4 x 80 GB SSD | 32 GB (upgradeable to 64 GB) | 10 GB (upgradeable to 41 GB) |
EX1260-4 VH version | EXA-01260-B085 | 2 x 6 cores 2.6 GHz | 1 x 6 cores / 1 x 6 cores | 4 x 1 TB HDD 4 x 80 GB SSD | 88 GB | 64 GB |
EX1360 G/L/M versions | EXA-01360-B010 | 2 x 8 cores 3.0 GHz | 1 x 8 core / 1 x 8 cores | 20 x 1 TB HDD 4 x 100 GB SSD | 128 GB | 64 GB |
EX1360P G/L/M versions | EXA-01360-B030 | 2 x 8 cores 3.0 GHz | 1 x 8 core / 1 x 8 cores | 20 x 1 TB HDD 4 x 400 GB SSD | 128 GB | 64 GB |
Series | SteelFusion-only allocation (extended disk layout) | VSP-only allocation (extended disk layout) | Mixed allocation (extended disk layout) | SteelFusion IOPS |
EX560/EX760 | 380 (380) | 380 (600) | 190 (300) | 85 |
EX1160 | 760 (760) | 415 (830) | 275 (415) | 170 |
EX1260-2 | 1580 (1580) | 860 (1700) | 575 (860) | 350 |
EX1260-4 | 3.6TB (3.6TB) | 1.86TB (3.7TB) | 1230 (1860) | 700 |
EX1360 | 10TB | 10TB | 4TB (5TB) | 1700 |