Configuration Mode Commands : SteelHead (in the cloud) Feature Commands : discovery enable : license server
  
license server
Syntax
[no} license server <hostname> [priority <number>] [port <number>]
Parameters
<hostname>
Hostname of the computer that contains the license server.
priority <number>
Specifies the order in which the license server is added. 0 is the highest priority and 9 is the lowest priority. The default priority is 9.
port <number>
Specifies the port number on which the license server is listening. The default is port 80.
Usage
The license server provides licenses to the appliance. This command is only relevant for SteelHead-c licensing using the Riverbed Cloud Portal.
The no command option deletes the license server specified.
The default license server is the server hosted at Riverbed headquarters.
The no license server <hostname> priority command resets the priority in which the specified license server is added to the default value (9 is the lowest priority).
The no license server <hostname> port command resets the license server port to the default port.
Example
amnesiac (config) # license server MyLicenseServer
amnesiac (config) # show license-servers
Server Name Port Priority
--------------- --------------- ---------------
MyLicenseServer 80 0
Product
SteelHead-c
Related Commands
show license-servers
Displaying SteelHead (in the cloud) Information