Configuration Mode Commands : SteelCentral Controller for SteelHead Mobile Commands : Policy Commands : policy id in-path rule edit rulenum discard
  
policy id in-path rule edit rulenum discard
Edits an in-path rule that drops connections on the specified policy.
Syntax
[no] policy id <id> in-path rule edit rulenum <rulenum> discard [srcaddr <subnet>] [dstaddr <subnet>] [dstport <port>] | [description <description>] [rule-enable {true | false}]
Parameters
<id>
Policy ID number.
rulenum <rulenum>
Rule number to edit: 1-N or start or end.
srcaddr <subnet>
Specifies the source subnet, for this rule in the format XXX.XXX.XXX.XXX/XX.
dstaddr <subnet>
dstport <port>
Specifies the destination subnet and port for this rule.
For the subnet address, use the format XXX.XXX.XXX.XXX/XX.
For the port, you can specify a single port (number), a port label, or all to specify all ports.
description <description>
Specifies a description of the rule.
rule-enable
Enables (true) or disables (false) an in-path rule.
Usage
Use the in-path rule discard command to add an in-path rule that drops connections.
For detailed information about in-path rules, see the SteelHead Management Console User’s Guide.
Example
amnesiac (config) # policy id 1 in-path rule edit rulenum 2 discard srcaddr 10.0.0.1/24 dstaddr 10.0.0.2/24 description example rule-enable true
Product
Mobile Controller
Related Commands
show policy id