Configuration Mode Commands : SteelHead EX Commands : Storage Commands : device-failover peer set
  
device-failover peer set
Specifies and sets the failover peer settings for the BlockStream-enabled SteelHead EX.
Syntax
device-failover peer set <serial-number> ip <address> local-if <local-interface-name> additional-ip <additional-ip> local-if2 <local-interface-name2> edge-id <edge-id> [local-if-dc <local-interface-name>]
Parameters
<serial-number>
Serial number of the SteelHead EX active peer.
ip <address>
Specifies the IP address of the SteelFusion Edge active peer appliance.
local-if <local-interface-name>
Specifies the local interface for the standby peer to connect to the active peer.
additional-ip <additional-ip>
Specifies the IP address of the SteelFusion Edge active peer, which is different from the first peer IP address specified by the ip <address> parameter.
local-if2 <local-interface-name2>
Specifies the second local interface name for the standby peer to connect to the second IP address specified by the additional-ip <additional-ip> parameter.
edge-id <edge-id>
Specifies the self-identifier for the active peer. This value is case-sensitive and limited to the following characters: 0 through 9, a through z, A through Z, period (.), and hyphen (-).
Both peer appliances must use the same self identifier. In this case, you can use a value that represents the group of appliances.
local-if-dc <local-interface-name>
Specifies the local interface for the current appliance to use when connecting with the SteelFusion Core appliance.
Usage
This command configures the failover peer settings to provide high availability between BlockStream-enabled SteelHeads. High availability enables you to configure two Edge appliances so that either one can fail without disrupting the service of the LUNs being provided by SteelFusion Core.
Example
Edge1 (config) # device-failover peer set DA3XS000085C5 ip 10.2.2.2 local-if primary additional-ip 10.3.2.2 local-if2 wan0_0 edge-id branch12
Product
SteelHead EX
Related Commands
show device-failover