Configuration Mode Commands : SteelHead Configuration Commands : Domain and Workgroup Commands : domain rejoin
  
domain rejoin
Rejoins a domain.
Syntax
domain rejoin login <login> password <password> [dc-list <dc-list>] [join-type {workstation | win2k8-mode | win2k3-mode}] [short-name <name>] [netbios-name <name>]
Parameters
login <login>
Specifies the login for the domain. The login and password are not stored.
Note: This account must have domain-join privileges; it does not need to be a domain administrator account.
password <password>
Specifies the domain password. The password is not stored.
dc-list <dc-list>
Specifies a list of domain controller names, separated by commas.
The dc-list parameter is required when the join type is win2k8-mode. The DC list should contain only the names or IP addresses of Windows 2008 and later domain controllers.
join-type
Specifies the join account type in which the server-side SteelHead can join the domain in one of the following roles:
•  workstation - Joins the server-side SteelHead appliance to the domain with workstation privilege. You can join the domain to this account type using any ordinary user account that has the permission to join a machine to the domain.
•  win2k8-mode - Specifies Active Directory integrated (Windows 2008 and later).
•  win2k3-mode - Specifies Active Directory integrated (Windows 2003).
If you do not specify a join type, the SteelHead uses the default behavior and joins the domain as a workstation join type.
The dc-list parameter is required when the join type is win2k8-mode. The DC list should only contain the names or IP addresses of Windows 2008 and higher domain controllers.
short-name <name>
Specifies a short domain name. Typically, the short domain name is a substring of the realm. In rare situations, this is not the case, and you must explicitly specify the short domain name. Case matters; NBTTECH is not the same as nbttech.
The short domain name is required if the NetBIOS domain name does not match the first portion of the Active Directory domain name.
netbios-name <name>
Specifies a NetBIOS name.
The short domain name is required if the NetBIOS domain name does not match the first portion of the Active Directory domain name.
Usage
The SteelHead rejoins the same domain as specified by the domain join command.
Example
amnesiac (config) # domain rejoin login admin password mypassword
Product
SteelHead CX, SteelHead EX, SteelHead-v, SteelHead-c
Related Commands
domain join, show domain