Configuration Mode Commands : SteelHead Configuration Commands : Top Talkers Commands : stats settings top-talkers interval
  
stats settings top-talkers interval
Enables Top Talkers collection period.
Syntax
stats settings top-talkers interval <hours>
Parameters
<hours>
Interval in hours: 24 or 48 hours.
Usage
This command specifies a time period to adjust the collection interval:
•  24-hour Report Period - For a five-minute granularity (the default setting).
•  48-hour Report Period - For a ten-minute granularity.
Example
amnesiac (config) # stats settings top-talkers interval 24
Product
SteelHead CX, SteelHead EX, SteelHead-v, SteelHead-c
Related Commands
show stats top-talkers
Application Commands
This section describes the application commands that are used with path selection and QoS.