Configuration Mode Commands : SteelHead Configuration Commands : In-Path and Virtual In-Path Support Commands : in-path lsp enable
  
in-path lsp enable
Enables link state propagation.
Syntax
[no] in-path lsp enable
Parameters
None
Usage
If you require a SteelHead to fail-to-wire (bypass) when the LAN or WAN ports become disconnected, enable this command. For example, if the LAN interface drops the link then the WAN also drops the link. Link state propagation (LSP) is on by default. This feature is similar to what ISPs do in order to follow the state of a link.
You cannot reach a MIP interface when link state propagation is also enabled and the corresponding in-path interface fails. In physical in-path deployments, LSP shortens the recovery time of a link failure. LSP communicates link status between the devices connected to the SteelHead and is enabled by default in RiOS v6.0 and later.
The no command option disables the link-state propagation.
Example
amnesiac (config) # in-path lsp enable
Product
Interceptor, SteelHead CX, SteelHead EX, SteelHead-v, SteelHead-c
Related Commands
show in-path lsp