SteelConnect SDI-2030 and SDI-5030 Gateway Specifications
This appendix describes the technical and environmental specifications for the SteelConnect SDI-2030 and SDI-5030 gateways.
SDI-2030 gateway technical specifications
SDI-5030 gateway technical specifications
SDI-2030 gateway technical specifications
Specification
Definition
Form factor
1U
CPU
1x E5-2620v4
The SDI-2030 gateway does not contain a second CPU in socket 2.
DIMM slots E1,E2, E3, G1, G2, G3 are empty.
Total no. of cores
8
Physical Interfaces
2 x 10 GbE ports (RJ45 ports 5 and 6)
4 x 1 GbE ports via base configuration NIC (ports1, 2, 3, and 4)
Riser-card slot 1
PCIe expansion slot (ports 7, 8. 9. and 10)
Riser-card slot 2
Not configurable (not connected to a CPU)
Hard drive disk
1x 3.5 1TB SATA HDD
Memory
4x 8GB DDR4 = 32GB
Dimensions
With bracket and power supply handle
1.72 in. (43.6 mm) x 17.25 in. (439 mm) x 30.25 in. (769 mm)
Without bracket and power supply handle
1.72 in. (43.6 mm) x 17.25 in. (439 mm) x 28 in. (712 mm)
Weight
33 lb (14.96 kg)
Voltage frequency
47 to 63 Hz
Power supply unit x 2
750 W
IOM NIC
Four-Port 1GbE Copper Base-T
Power requirements and consumption
This table summarizes the power specifications for the gateway. The gateway is rated at the following power characteristics when operating at nominal AC input voltages (110 V and 220 V).
Specification
Definition
Configuration
1 + 1 redundant power
PSU type
2 x 750 W
AC input
90 to 130 on 110 V systems, 180-260 on 220 V systems
Typical Watts
285 W
Power factor
50% load >90%
BTU (typical)
972
Environmental specifications
Specification
Definition
Operating acoustic
7.0 BA
Temperature (operating)
50ºF to 95ºF (10ºC to 35ºC)
Temperature (storage)
-40ºF to 158ºF (-40ºC to 70ºC)
Relative humidity
50 to 90%, noncondensing
Altitude (operating)
10,000 ft (3050 m)
SDI-5030 gateway technical specifications
Specification
Definition
Form factor
1U
CPU
2x E5-2620v4
Total no. of cores
16
Physical Interfaces
2 x 10 GbE ports (RJ45 ports 5 and 6)
4 x 1 GbE ports via base configuration NIC (ports1, 2, 3, and 4)
Riser-card slot 1
PCIe expansion slot (ports 7, 8. 9. and 10)
Riser-card slot 2
Not configurable (preinstalled offload compression NIC)
Hard drive disk
1 x 3.5 in 1 TB SATA HDD
Memory
8 x 16GB DDR4 = 128 GB
Dimensions
With bracket and power supply handle
1.72 in. (43.6 mm) x 17.25 in. (439 mm) x 30.25 in. (769 mm)
Without bracket and power supply handle
1.72 in. (43.6 mm) x 17.25 in. (439 mm) x 28 in. (712 mm)
Weight
33 lb (14.96 kg)
Voltage frequency
47 to 63 Hz
Power supply unit x 2
750 W
IOM NIC
Four-Port 1-GbE Copper Base-T
Power requirements and consumption
This table summarizes the power specifications for the gateway. The gateway is rated at the following power characteristics when operating at nominal AC input voltages (110 V and 220 V).
Specification
Definition
Configuration
1 + 1 redundant power
PSU type
2 x 750 W
AC input
90 to 130 on 110 V systems, 180-260 on 220 V systems
Typical Watts
285 W
Power factor
50% load >90%
BTU (typical)
972
Environmental specifications
Specification
Definition
Operating acoustic
7.0 BA
Temperature (operating)
50ºF to 95ºF (10ºC to 35ºC)
Temperature (storage)
-40ºF to 158ºF (-40ºC to 70ºC)
Relative humidity
50 to 90%, noncondensing
Altitude (operating)
10,000 ft (3050 m)