LED | Status |
System | Healthy = Blue Degraded = Yellow Critical = Red Power Off = None |
Power Button LED | System Off = No Light Standby Mode = Yellow Power On = Blue |
Primary LED | Left LED Link = Green Activity = Blinks Green Right LED GB = Yellow 100 MB = Green 10 MB = No Light (with link on left LED) |
LAN/WAN LEDs | Left LED Link = Green Activity = Blinks Green Bypass/Disconnect = Yellow Right LED GB = Yellow 100 MB = Green 10 MB = No Light (with link on left LED) |
CX255 Desktop P-U-L-M-H | |
Power (typical) | 30 W |
VA (max) | 63.8 |
BTU | 102 BTU |
Hard disk | 320 GB |
Data store | 50 GB |
Dimensions (LxWxH) | 13x8x1.73 in 330x204x44mm |
Weight (without packaging) | 5.5 lbs 2.4 kg |
Voltage frequency | 100-240V 50 - 60 Hz |
PSU | Single 84 W External 100-240Vac, 50/60Hz, 2-1 A |
Onboard bypass ports/max # ports | 2 |
CX255 | |
Operating acoustic | 45 dBA Sound pressure (Typical) |
Temperature (operating) | 0º - 45º C 32º - 113º F |
Temperature (storage) | -40º - 65º C -40º - 149º F |
Relative humidity | 20% - 80% noncondensing |
Storage humidity | 5% - 95% noncondensing |
LED | Status |
SYSTEM | Healthy = Blue Degraded = Yellow Critical = Red System Boot = Yellow Note: When the appliance is powered down with the power connected (for example, after running a reload halt command), the color of the system LED is undefined and carries no significance. The color can be either red, orange, or purple, depending on the state of the LED prior to shutdown. |
HDD ACT | HDD Activity = Blinks Blue |
BYP/BLK (Bypass or Block (Disconnect) Mode) | Normal = No Light Bypass or Block (Disconnect) = Orange |
HDD ALARM | Disk Connected = Blue Read/Write Activity = Blinks Blue Failed Disk = Orange |
LAN-WAN LEDs | Left LED Link = Green Activity = Blinks Green Right LED GB = Green 100-MB = Orange 10-MB = No Light |
CX555 Desktop M-H | CX755 Desktop L-M-H | |
Power (typical) | 45 W | 50 W |
VA (max) | 62.5 | 66.5 |
BTU | 145 BTU | 165 BTU |
Hard disk | 2 x 250 GB | 2 x 250 GB H= 1 x 250 GB HDD + 1 x 160 SSD |
Data store | 80 GB | 100-160 GB |
Dimensions (LxWxH) | 7.1x12x1.65 in 180.3x304.8x42 mm | 7.1x12x1.65 in 180.3x304.8x42 mm |
Weight (without packaging) | 4.7 lbs 2.15 kg | 4.7 lbs 2.15 kg |
Voltage frequency | 100-127V, 200-240V | 100-127V, 200-240V |
PSU | Single 100 W Internal 100-240Vac, 50/60Hz, 2-1 A | Single 100 W Internal 100-240Vac, 50/60Hz, 2-1 A |
Onboard bypass ports/max # ports | 4 | 4 |
CX555 | CX755 | |
Operating acoustic | 45 dBA Sound pressure (Typical) | 45 dBA Sound pressure (Typical) |
Temperature (operating) | 0º - 45º C 32º - 113º F | 0º - 45º C 32º - 113º F |
Temperature (storage) | -40º - 65º C -40º - 149º F | -40º - 65º C -40º - 149º F |
Relative humidity | 20% - 80% noncondensing | 20% - 80% noncondensing |
Storage humidity | 5% - 95% noncondensing | 5% - 95% noncondensing |
LED | Status |
SYSTEM | Healthy = Blue Degraded = Yellow Critical = Red System Boot = Yellow |
PRI = Primary AUX = Auxiliary REM = Remote | Link and Traffic = Blinks Blue |
LAN-WAN | Link and Traffic = Blinks Blue |
BYP/BLK BYP = Bypass BLK = Block (Disconnect) | Normal = No Light Bypass or Block (Disconnect) = Orange |
HDDs/SSDs | Activity LED Disk Connected = Blue Read/Write Activity = Blinks Blue Disk Fault LED Failed Disk = Orange |
Back Panel PRI = Primary AUX = Auxiliary REM = Remote | Left LED Link = Green Activity = Blinks Green Right LED GB = Orange 100 MB = Green (REM only at 100 MB) 10 MB = No Light |
Back Panel LAN-WAN | Left LED Link = Green Activity = Blinks Green Right LED GB = Orange 100 MB = Green 10 MB = No Light BYP/BLK Normal = No Light Bypass or Block (Disconnect) = Orange |
CX1555 L/M | CX1555 H | |
Form factor | 1 U | 1U |
Hard disk | 2 x 250 GB | 2 x 500 GB, 2 SSD x 160 |
Data store | 400 GB | 320 GB SSD |
Dimensions (LxWxH) | 25.4x17.2x1.71 in 645.4x436x43.5 mm | 25.4x17.2x1.71 in 645.4x436x43.5 mm |
Weight (without packaging) | 36 lbs 16.36 kg | 36 lbs 16.36 kg |
Voltage frequency | 100-127V, 200-240V | 100-127V, 200-240V |
PSU | 2 x 450 W 100-127Vac/8A, 50/60Hz 200-240Vac/4A, 50/60Hz | 2 x 450 W 100-127Vac/8A, 50/60Hz 200-240Vac/4A, 50/60Hz |
PCI slots | 2 | 2 |
Onboard bypass ports/max # ports | 4/12 | 4/12 |
System | CX1555 | CX1555 |
Configuration | All (L/M/H) | All (L/M/H) |
PSU Type | 2 x 450W | 2 x 450W |
AC Input | 120V | 230V |
Max. Amps. | 4.1 | 3.4 |
Max. Watts | 220 | 220 |
Typical Watts | 175 | 180 |
Max VA | 225 | 265 |
Power Factor | 97 | 92 |
BTU (Typical) | 605 | 610 |
CX1555 | |
Operating acoustic | 61.6 dBA Sound Pressure (Typical) |
Temperature (operating) | 10º - 40º C 50° - 104º F |
Temperature (storage) | -40º - 65º C -40º - 149º F |
Relative humidity | 20% - 80% noncondensing |
Storage humidity | 5% - 95% noncondensing |
LED | Status |
SYSTEM | Normal = Blue System Boot = Yellow |
PRI = Primary AUX = Auxiliary REM = Remote | Link and Traffic = Blinks Blue |
LAN-WAN | Link and Traffic = Blinks Blue |
BYP/BLK BYP = Bypass BLK = Block (Disconnect) | Normal = No Light Bypass or Block (Disconnect) = Orange |
HDDs/SSDs | Activity LED Disk Connected = Blue Read/Write Activity = Blinks Blue Disk Fault LED Failed Disk = Orange |
Back Panel PRI = Primary AUX = Auxiliary REM = Remote | Left LED Link = Green Activity = Blinks Green Right LED GB = Orange 100 MB = Green (REM only at 100 MB) 10 MB = No Light |
Back Panel LAN-WAN | Left LED Link = Green Activity = Blinks Green Right LED GB = Orange 100 MB = Green 10 MB = No Light BYP/BLK Normal = No Light Bypass or Block (Disconnect) = Orange |
CX5055 L/M | CX7055 L | CX7055 M | CX7055 H | |
Form factor | 2 U | 2 U | 2 U | 2 U |
Hard disk/SSD | 2 x 500 GB HDD 8 x 80GB SSDs | 2 x 500 GB HDD 10 x 160 GB SSDs | 2 x 500 GB HDD 15 x 160 GB SSD | 2 x 500 GB HDD 16 x 300 GB SSD |
Data store | 640 GB SSD | 1.6 TB SSD | 2.4 TB SSD | 4.8 TB SSD |
Dimensions (LxWxH) | 25.4x17.2x3.43 in 645.4x436x87.1 mm | 25.4x17.2x3.43 in 645.4x436x87.1 mm | 25.4x17.2x3.43 in 645.4x436x87.1 mm | 25.4x17.2x3.43 in 645.4x436x87.1 mm |
Weight (without packaging) | 52 lbs/23.6 kg | 54 lbs/24.5 kg | 54 lbs/24.5 kg | 54 lbs/ 4.5 kg |
Voltage frequency | 100-127V, 200-240V | 100-127V, 200-240V | 100-127V, 200-240V | 100-127V, 200-240V |
PSU | 2 x 770W 100-127Vac/8A, 50/60Hz 200-240Vac/4A, 50/60Hz | 2 x 770W 100-127Vac/8A, 50/60Hz 200-240Vac/4A, 50/60Hz | 2 x 770W 100-127Vac/8A, 50/60Hz 200-240Vac/4A, 50/60Hz | 2 x 770W 100-127Vac/8A, 50/60Hz 200-240Vac/4A, 50/60Hz |
PCI slots | 4 | 4 | 4 | 4 |
Onboard bypass ports/max # ports | 4/20 | 4/20 | 4/20 | 4/20 |
System | CX5055 | CX7055 | ||
Configuration | All (M/H) | All (L/M/H) | ||
PSU type | 2 x 770W | 2 x 770W | ||
AC input | 120V | 230V | 120V | 230V |
Max. amps. | 4.9 | 2.5 | 5.3 | 2.8 |
Max. watts | 470 | 465 | 525 | 510 |
Typical watts | 375 | 375 | 420 | 410 |
Max VA | 480 | 480 | 530 | 525 |
Power factor | 98 | 97 | 98 | 97 |
BTU (typical) | 1280 | 1275 | 1425 | 1390 |
CX5055 | CX7055 | |
Operating acoustic | 65.5 dBa Sound Pressure (Typical) | 65.5 dBa Sound Pressure (Typical) |
Temperature (operating) | 10º - 40º C 50° - 104º F | 10º - 40º C 50° - 104º F |
Temperature (storage) | -40º - 65º C -40º - 149º F | -40º - 65º C -40º - 149º F |
Relative humidity | 20% - 80% noncondensing | 20% - 80% noncondensing |
Storage humidity | 5% - 95% noncondensing | 5% - 95% noncondensing |