Topologies
Supported topologies
This section describes many, but not all, of the supported topologies in SteelConnect for the branches and the data center. For all topologies, configuring high availability improves the reliability of a network by replacing a single SteelConnect gateway with two gateways in the branch or three gateways in the data center. A backup gateway can maintain network traffic if another gateway fails. For details, see How does branch high availability work? and How does data center high availability work?.
Branch topologies
Single router using NAT to the internet
Router using NAT
The following topologies support a single router using network address translation (NAT).
DHCP or static IP address for the uplink
A location connects to the internet using a single router or a DSL modem. You can deploy a SteelConnect gateway on the LAN side of the router with its default configuration and it will perform NAT as well. This topology works fine for most deployments. If you have port forwarding configured on the router, you’d have to configure the port forwarding on the gateway as well.
Turn off outbound NAT
Outbound NAT forwards the client's connections with their original source IP to the router. For deployments where an upstream gateway, router, or firewall will perform NAT, you can turn off outbound NAT. When outbound NAT is off, the existing router is no longer directly connected to the IP subnets used in the LAN, but sends traffic to the gateway. The gateway performs NAT and forwards traffic to the zones.
You can’t turn off outbound NAT per gateway. You can turn off outbound NAT per zone, sites, and uplinks. For details, see Turning off outbound NAT.
Skipping outbound NAT
Reconfigure the router to function as a DSL modem or bridge
In this deployment, you need to configure the Point-to-Point Protocol over Ethernet (PPPoE) credentials on the gateway so it can authenticate with the internet service provider. This typically means that the customer enters a user name and password provided by the ISP to use that last-mile link from the customer premises to the ISP. The gateway then connects to the internet using NAT and routes traffic between the configured zones and the internet.
 
Single router to an MPLS network
This topology is similar to the previous description of a single router using NAT, except that the router connects to an MPLS network.
One router connecting to MPLS
The gateway must connect to the internet either through the MPLS network or through a local internet breakout to connect to the SteelConnect cloud service.
You must map the static IP address for the gateway’s uplink to the IP address of the LAN interface on the router. To ensure that the zones on the LAN side of the gateway can be reached, you must also configure static routes for the zone’s subnets on the router.
To set up a VPN over the MPLS network, configure the uplink of the gateway to propagate the internal IP address that the remote sites use as the endpoint target for the AutoVPN tunnel. By default, SCM uses the external IP address facing the internet. For details, see To configure an uplink to use an internal interface.
Two routers active-backup
The following topologies support two routers.
Single network: internet/MPLS
This topology deploys two routers connecting to the same network where one router is actively forwarding traffic and the second router is acting as backup for the first. In this topology, it doesn’t make a difference if the network were trying to connect to the internet or a private network such as MPLS. For a description of the challenges connecting to the internet versus connecting to a private network, see Single router to an MPLS network.
To connect a SteelConnect gateway to two routers, you need to create two uplinks configured with different IP addresses. Then you need to configure one of the uplinks as backup only.
To monitor the active uplink, the SteelConnect gateway performs a traceroute to the configured DNS and pings the third answering device on the path every ten seconds. After the uplink misses five consecutive pings, SteelConnect considers the uplink to be down and the backup uplink becomes active. At the same time, the system monitors the link status. If the active uplink is down, the backup uplink becomes active immediately. For details on creating a backup uplink, see Creating uplinks.
Two routers active-backup
Two routers active-active
This topology deploys two routers connecting to the same network where both routers are actively forwarding traffic. In this topology, you connect a SteelConnect gateway to the routers by creating two uplinks configured with different IP addresses. There is nothing additional to configure.
The SteelConnect gateway automatically load balances the sessions over the two uplinks based on source and destination IP addresses.
Two routers active-active
Dual internet through two ISPs
This topology has dual Internet connectivity via two different Internet Service Providers (ISPs). The traffic outbound is automatically load balanced by the gateway when both uplinks connect to the same WAN (internet). The system uses the source IP to load balance internet-bound traffic, and the source and destination IP to load balance RouteVPN traffic.
You can also configure this topology as active-backup.
Two routers connecting to the internet with different ISPs
Internet and MPLS
This topology is very similar to the previous deployment except instead of two internet connections there is one connection to the internet and one connection to a private network, typically MPLS. As in the previous topologies, you connect a SteelConnect gateway to the routers by creating two uplinks configured with different IP addresses. Next, choose to do either automatic load balancing or path selection. For path selection, the SteelConnect gateway must have a Layer 2 connection to the routers to perform MAC address rewriting.
For this topology, on the gateway uplink to the MPLS router, you also need to configure a static route to the MPLS network. For details, see Single router to an MPLS network. You must also configure static routes to zones on the MPLS router.
One connection to the internet, one connection to MPLS
Dual MPLS
This topology has two connections to private networks, most likely MPLS. In this topology the SteelConnect gateway needs a connection to the internet to reach the cloud controller. The internet connection can’t use a proxy.
You create two uplinks with different IP addresses. Next, choose to do either automatic load balancing or path selection. For path selection, the SteelConnect gateway must have a Layer 2 connection to the routers to perform MAC address rewriting.
For this topology, on the gateway uplink to the MPLS router, you need to configure a static route to the MPLS network. For details, see Single router to an MPLS network. You must also configure static routes to zones on the MPLS router.
Two connections to private networks
Data center topology
A 5030 gateway is the data center side of SteelConnect. In contrast to the branch gateways that handle the in-path traffic, the data center gateway sits out of path deep inside the data center’s network.
Data center, Interceptor, and branch gateway deployment
Data center, Interceptor, and branch gateway deployment shows four SteelHead Interceptor 9600s placed between the LAN switching and WAN aggregation routing layers. On the LAN side of the SteelHead Interceptors, three SteelHead CXs provide WAN optimization. On the WAN side of the SteelHead Interceptors, three 5030 gateways are connected physically (or by switching) to the WAN aggregation routers.
All VPN tunnels exist between the branch gateways and the 5030 gateways behind the aggregation layer. The SteelHead Interceptors always see nonencrypted traffic, enabling them to redirect the flows to the SteelHead CXs for WAN optimization.
Topology options
Local internet breakout or backhaul
When sending traffic to the internet, a SteelConnect access point or gateway uses direct internet uplinks by default for the local breakout. You can configure a backhaul site, or a local internet breakout for each network, similar to a default route. SteelConnect sends any traffic with an unknown destination network; that is, the destination is not configured in a site or a zone, to the specified site, or to the local internet breakout.
You can set the internet breakout preference to RouteVPN, which is essentially a WAN over the internet resulting from AutoVPN, or to a WAN defined for an organization. You can override the default on the network, site, or zone level. You can define multiple internet breakouts within an organization. For more information, see Adding zone details.
Internet traffic breakout or backhaul
In SteelConnect, the terms RouteVPN and AutoVPN are interchangeable.
Remote access
An agent for Windows or Mac is available for download to provide remote client access for traveling users. The advantage of using the agent is that you can configure remote user policy centrally on SCM. After downloading, installing, and registering the agent, the user connects to a site’s zone as if they were physically located there. The same user policy is applied no matter where they are working. By default, all agents connect to the same site. For details, see Agent.
Remote access through an agent for Windows
Connect cloud services
The SteelConnect gateway virtual machine (VM) is available for various virtualization platforms in these image types:
VMware
Virtualbox
KVM
Hyper-V
XENCenter
Amazon EC2
When you deploy a gateway in your cloud or multiple clouds, the RouteVPN feature lets you connect your data center to the cloud, or even multiple clouds with each other.