Network Card Status Lights for SteelHead and SteelCentral xx80 Appliances
  
Network Card Status Lights for SteelHead and SteelCentral xx80 Appliances
This appendix summarizes the network add-on cards status lights for the SteelHead and SteelCentral xx80 appliances. It includes these sections:
Four-Port 1-GbE Copper Bypass card
Four-Port 1-GbE Fiber SX card
Four-Port 1-GbE Fiber LX card
Four-Port 10-GbE Fiber SR card
Four-Port 10-GbE Fiber LR card
Two-Port 40-GbE Fiber SR4 card
Two-Port 40-GbE Fiber LR4 card
Four-Port 1-GbE Fiber/Copper SFP card
Two-Port 10-GbE Fiber SFP+ card
Four-Port 10-GbE Fiber SFP+ card
Two-Port 40-GbE Time Stamp card
Two-Port 4/8/16-GbE FC HBA (SAN)
Two-Port 100-GbE QSPF+ Time Stamp Card
Four-Port 10-GbE DAC Redirector Card
This appendix assumes you have installed and configured the appliance. For details, see the installation and configuration guide for your product.
The physical ports on the NICs are mapped in proximity to the PCI bus edge connector. The port closest to the edge connector is L0, followed by W0, L1, and W1.
Four-Port 1-GbE Copper Bypass card
Two types of Four-Port 1-GbE Copper Bypass cards are available. Both can be installed in the 2U SteelHead CX5080 and CX7080 appliances. Type 2 cards are supported on software versions RiOS 9.9 or later
The physical ports on the NICs are mapped in proximity to the PCI bus edge connector. The port closest to the edge connector is L0, followed by W0, L1, and W1.
Figure A‑1. Four-Port Copper Bypass Type 1card (NIC-1-001G-4TX-BP)
Figure A‑2. Four-Port Copper Bypass Type 2 card (NIC-1-001G-4TX-BP)
 
Port
Description
L0, W0, L1, W1
Provides access to 10/100/1000 Base-T
 
LED
Type 1 definitions
Type 2 definitions
LINK/ACT
Link = Green
Activity = Blinks green
Link = Green
Activity = Blinks green
BYP/DISC. SPD
1000 Mbps = Yellow
100 Mbps = Green
10 Mbps = Off
Bypass = Blinks green
Disconnect = Blinks yellow
SPD
1000 Mbps = Orange
100 Mbps = Green
10 Mbps = Off
BYP1, BYP0
Disconnect = Yellow
Bypass = Green
Normal = Off
 
Specification
Descriptions
Connectors
Four shielded RJ-45
Cables and operating distance
10-Base-T Category 3, 4, or 5 maximum 50 m*
100-Base-TX Category 5 maximum 5m*
1000-Base-T Category 5E maximum 5E m*
*Theoretical distance is defined as half a distance as stated by the IEEE 802.3 standard.
Four-Port 1-GbE Fiber SX card
Two types of Four-Port 1-GbE cards are available. Both can be installed in the 2U SteelHead CX5080 and CX7080 appliances. Type 2 cards are supported on software versions RiOS 9.9 or later.l
The physical ports on the NICs are mapped in proximity to the PCI bus edge connector. The port closest to the edge connector is L0, then W0, L1, followed by W1.
Figure A‑3. Four-Port 1-GbE Fiber SX Type 1 card (NIC-1-001G-4SX-BP)
Figure A‑4. Four-Port 1-GbE Fiber SX Type 2 card (NIC-1-001G-4SX-BP)
 
Port
Description
L0, W0, L1, W1
TX and RX provides access to 1000 Base-SX
 
LED
Type 1 definitions
Type 2 definitions
LNK
Link = Green
LNK/ACT
Link = Green
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
Normal = Off
Disconnect = Yellow
Bypass = Green
ACT
On = Blinks orange
 
Specification
Definition
Connectors
Four small form factor (SFF) LC fiber connectors
Cables and operating distance
Multimode fiber = 137 m maximum at 62.5 m cable (half of theoretical distance of IEEE 802.3 standard)
Four-Port 1-GbE Fiber LX card
Figure A‑5. 4-Port 1-GbE Fiber LX (NIC-1-001G-4LX-BP)
 
Port
Description
L0, W0, L1, W1
TX and RX provides access to 1000 Base-LX
 
LED
Definition
LINK/ACT
Link = Green
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specifications
Description
Connectors
Four small form factor (SFF) LC fiber connectors
Cables and operating distance
Single-mode fiber: 9 micrometers
2500 m maximum at 9 micrometers*
* Theoretical distance is defined as half a distance as stated by the IEEE 802.3 standard.
 
Four-Port 10-GbE Fiber SR card
The four-port 10-GbE fiber SR NICs have a power connector cable attached that is not used in the Riverbed SteelHead platforms. The SteelHead systems are designed to fully power these NICs through the interface bus.
Figure 6‑10. Four-Port 10-GbE Fiber SR Card (NIC-1-010G-4SR-BP)
 
Port
Description
P0, P1, P2, P3
P0, P1, P2, P3 provide access to 10 G-Base-SR
 
LED
Definition
LINK/Activity
Link = Yellow on 1 GB
Link = Green on 10 GB
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specification
Definition
Connectors
Four small form factor (SFF) LC fiber connectors
Cables and operating distance
Multimode fiber:
62.5um, 160MHz/Km 13m
62.5um, (OM1)200MHz/Km 16.5m
50um, 400MHz/Km 33m
50um, (OM2)500 MHz/Km 41m
50um, (OM3)2000MHz/Km 150m
All distances are defined as half a distance as specified in the optical transceiver.
Four-Port 10-GbE Fiber LR card
The four-port 10-GbE fiber LR NICs have a power connector cable attached that is not used in the Riverbed SteelHead platforms. The SteelHead systems are designed to fully power these NICs through the interface bus.
Figure 6‑11. Four-Port 10-GbE Fiber LR Card (NIC-1-010G-4LR-BP)
 
Port
Description
P0, P1
P0, P1, P2, and P3 provide access to 10 G-Base-LR4
 
LED
Definition
LINK/Activity
Link = Yellow on 1 GB
Link = Green on 10 GB
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specification
Definition
Connectors
Four small form factor (SFF) LC fiber connectors
Cables and operating distance
Singlemode fiber
9u, maximum 5 km
All distances are defined as half a distance as specified in the optical transceiver.
Two-Port 40-GbE Fiber SR4 card
Figure 6‑12. Two-Port 40-GbE Fiber SR4 Card (NIC-1-040G-2SR4-BP)
 
Port
Description
P0, P1
P0 and P1 provide access to 40GBase-SR
 
LED
Definition
LINK/Activity
Link = Green
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specification
Definition
Connectors
Four small form factor MTP-MTP fiber connectors
Cables and operating distance
Multimode Fiber
0.5 to 50 m using 50 micrometers, (OM3) 1500 MHz Km
0.5 to 75 m using 50 micrometers, (OM4) 3500 MHz Km
All distances are defined as half a distance as specified in the optical transceiver.
Two-Port 40-GbE Fiber LR4 card
Figure 6‑13. Two-Port 40 GbE Fiber LR4 Card (NIC-1-040G-2LR4-BP)
 
Port
Description
P0, P1
P0 and P1 provide access to 40GBase-LR4
 
LED
Definition
LINK/Activity
Link = Green
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specification
Definition
Connectors
Four small form factor (SFF) LC fiber connectors
Cables and operating distance
5km using SMF-28 cables
Distance is defined as half of the distance as specified in the optical transceiver.
Four-Port 1-GbE Fiber/Copper SFP card
Figure A‑6. Four-Port 1-GbE Fiber/Copper SFP Card (NIC-1-001G-4SFP)
 
Port
Description
P0, P1, P2, P3
Provides access to 1000 Base-TX, LX, or SX
 
LED
Description
LNK
Yellow
LNK/ACT
Link = Green
Activity = Blinks green
 
Specification
Description
Connectors
Four small form factor pluggable (SFP) cage
Cables and operating distances
SFP 1GBase-Copper module
1000 Base-T Category 5E maximum 100 m
SFP 1GBase-SX module
Multimode Fiber:
220 m using 62.5 micrometers
550 m using 50 micrometers
SFP 1GBase-LX module
Single-mode Fiber: 5000 m using 9 micrometers
Multimode Fiber: 550 m using 50 micrometers
550 m using 62.5 micrometers
 
Supported SFPs
Manufacturing part #
Orderable part #
SFP 1 GbE Copper module
410-00138-01
TRC-1-SFP-TX-C
SFP 1 GbE SX
410-00139-01
TRC-1-SFP-SX
SFP 1 GbE LX
410-00140-01
TRC-1-SFP-LX
Two-Port 10-GbE Fiber SFP+ card
Figure A‑7. Two-Port 10-GbE Fiber SFP+ (NIC-1-010G-2SFPP)
 
Port
Description
P0, P1, P2, P3
Provides access to 10 G-Base-SR, LR, or DAC
 
LED
Description
LINK P0, LNK P1
Green
LINK/ACT
Link= Green
Activity = Blinks green
 
Specification
Description
Connectors
Two small form factor pluggable (SFP+) cage
Cables and operating distance for the supported SFPs
SFP+ 10 GbE Direct Attached Cable
10-G Passive Direct Attach Cable, up to 10 meters
SFP+ 10GBase-SR module 62.5 um
160 MHz/km 26 m
62.5 micrometers, (OM1) 200 MHz/km 33 m
50 micrometers, 400 MHz/km 66 m
50 micrometers, (OM2) 500 MHz/km 82 m
50 micrometers, (OM3) 2000 MHz/km 300 m
SFP+ 10GBase-LR module
Single-Mode = 10000 m at 9 um
SFPs
Manufacturing part #
Orderable part #
SFP+ 10 GbE DAC
410-00140-01
TRC-1-SFPP-DAC-C
SFP+ 10 GbE SR
410-00143-01
TRC-1-SFPP-SR
SFP+ 10 GbE LR
410-00144-01
TRC-1-SFPP-LR
Four-Port 10-GbE Fiber SFP+ card
Figure A‑8. Four-Port 10-GbE Fiber SFP+ Card (NIC-1-010G-4SFPP)
 
LED
Description
Speed
Blue = 10 G
Yellow = 1 G (1 G not supported on SteelHead models.)
Link/Activity
Link = Green
Activity = Blinks green
 
Specification
Description
Connectors
Two small form factor pluggable (SFP+) cage
Cables and operating distance for the supported SFPs
SFP+ 10 GbE Direct Attached Cable
10-G Passive Direct Attach Cable, up to 10 meters
SFP+ 10GBase-SR module 62.5 um
160 MHz/km 26 m
62.5 micrometers, (OM1) 200 MHz/km 33 m
50 micrometers, 400 MHz/km 66 m
50 micrometers, (OM2) 500 MHz/km 82 m
50 micrometers, (OM3) 2000 MHz/km 300 m
SFP+ 10GBase-LR module
Single-mode = 10000 m at 9 micrometers
SFPs
Manufacturing part #
Orderable part #
SFP+ 10 GbE DAC
410-00140-01
TRC-1-SFPP-DAC-C
SFP+ 10-GbE SR
410-00143-01
TRC-1-SFPP-SR
SFP+ 10-GbE LR
410-00144-01
TRC-1-SFPP-LR
Two-Port 40-GbE Time Stamp card
Figure A‑9. Two-Port 40-GbE QSFP+ Time Stamp Card (NIC-1-040G-2QSFP-TS)
 
Network Interface
Description
IEEE standard
IEEE 802.3 40 Gbit/s Ethernet
Ports A, B
40-GbE QSFP+ Interfaces
Data Rate
2 x 40 Gbit/s
Supported QSFP+ modules
40G-BASE-SR4 (850 nm)
40G-BASE-LR4 (1310 nm)
 
Host Interface
Description
Physical bus connector
8-lane PCIe
PCIe bus type
1-8 lane PCIe Gen1/Gen2/Gen3
 
LED/Buttons
Description
Link/Activity
Link = Green
Activity = Orange
Panic = Red
PPS/Fail Safe
Not used
Two-Port 4/8/16-GbE FC HBA (SAN)
Network add-on card
Size
Manufacturing part #
Orderable part #
Two-Port 40GbE Time Stamp Card
HHHL
410-00214-01
NIC-1-040G-2QSFP-TS
Figure 6‑14. Two-Port fiber channel 4/8/16 GbE host bus adapter (SAN) Card (NIC-1-HBA-2FC)
 
Port
Description
Port A, B
Provide access to 40GBase-LR4
Dimensions
6.60” x 2.71” (167.64 mm x 68.91 mm)
Optical Data Rates
14.025 GbE (1600 Mbps)
8.5 GbE (800 Mbps)
4.25 GbE (400 Mbps, auto-detected)
Data Transfer Rates
Supports 16 GFC, 8 GFC, and 4 GFC link speeds, automatically negotiated
 
LED
Definition
LINK/Activity
Link = Green
Activity = Blinks green
Disconnect = Yellow
 
Specification
Definition
Connectors
LC type connectors
Cables and operating distance
100 m at 16-GbE on 50/125 micrometers OM3 MMF
125 m at 16-GbE on 50/125 micrometers OM4 MMF
15 m at 16-GbE on 62.5/125 micrometers OM1 MMF
35 m at 16-GbE on 50/125 micrometers OM2 MMF, Operating at 16Gb
Distance is defined as half of the distance as specified in the optical transceiver.
Two-Port 100-GbE QSPF+ Time Stamp Card
Figure A‑10. Two-Port 100-GbE QSFP+ Time Stamp Card (NIC-1-100G-2QSFP-TS)
 
Network Interface
Description
IEEE standard
IEEE 802.3 10-GE, 40-GE, 25-GE, 100-G
Ports A, B
QSFP28 ports
Data Rate
10-GbE and 25-GbE supported through break-out cable assemblies
Supported QSFP+ modules
25-GbE, 100-GbE
 
Host Interface
Description
Physical bus connector
16-lane PCIe
PCIe bus type
16 lane PCIe Gen3
 
LED
Description
Link/Activity
Link = Green
Activity = Orange
Error = Red
 
Specification
Description
Physical dimensions:
3/4 length, standard height
Four-Port 10-GbE DAC Redirector Card
Figure 6‑15. Four-Port 10-GbE DAC Card (NIC-1-010G-DAC-BP)
 
Port
Description
P0, P1, P2, P3
P0, P1, P2, and P3 provide access to 10GBase-R
 
LED
Definition
LINK/Activity
Link = Blue
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Blinks green
 
Specification
Definition
Cables and operating distance
62.5um, 160MHz/Km 13m
62.5um, (OM1)200MHz/Km 16.5m
All distances are defined as half a distance as specified in the optical transceiver.