Network Card Status Lights for SteelHead GX, xx70, SteelCentral, Interceptor, and SteelFusion Core
  
Network Card Status Lights for SteelHead GX, xx70, SteelCentral, Interceptor, and SteelFusion Core
This appendix summarizes the NIC status lights for the SteelHead GX, xx70, SteelCentral, Interceptor 9600, and SteelFusion Core 3500 appliances. It includes the these sections:
Four-Port 1-GbE Copper Bypass card
Two-Port 1-GbE Fiber SX card
Four-Port 1-GbE Fiber SX card
Two-Port 1-GbE Fiber LX card
Four-Port 1-GbE Fiber LX card
Two-Port 10-GbE Fiber SR card
Two-Port 10-GbE Fiber LR card
Two-Port 40-GbE Fiber SR4 card
Two-Port 40-GbE Fiber LR4 card
Four-Port 1-GbE Copper Base-T card
Two-Port 10-GbE Copper card
Four-Port 10-GbE Copper card
Four-Port 1-GbE Fiber/Copper SFP card
Two-Port 10-GbE Fiber SFP+ card
Two-Port 4/8/16-GbE FC HBA (SAN)
Four-Port 10-GbE Fiber SFP+ card
“Two-Port 40-GbE Time Stamp card” on page 137
Four-Port 10-GbE Fiber SR card
Four-Port 10-GbE Fiber LR card
Four-Port 10-GbE DAC redirector card
Four-Port 10-GbE Copper card
This appendix assumes you have installed and configured the appliance. For details, see the installation and configuration guide for your product.
The physical ports on the NICs are mapped in proximity to the PCI bus edge connector. The port closest to the edge connector is L0, then W0, L1, and W1.
For details on status lights and cards in the EX560 and EX760 appliances, see the Series EX560 and EX760 Systems Owner’s Manual.
Four-Port 1-GbE Copper Bypass card
Two types of Four-Port 1-GbE Copper Bypass cards are available. Both types can be installed in the 1U SteelHead CX 3070 and the 2U SteelHead CX 5070, SteelHead CX 7070 and the Interceptor 9600 appliances.
Type 2 cards are supported on the following software versions:
SteelHead versions: 8.6.0, 9.0.0, 9.1.0 and 9.2.0
Interceptor versions: 4.5.3, 5.5.0, and 5.0.1
The physical ports on the NICs are mapped in proximity to the PCI bus edge connector. The port closest to the edge connector is L0, then W0, L1, followed by W1.
Figure B‑1. Four-Port Copper Bypass Type 1 card (NIC-1-001G-4TX-BP)
Figure B‑2. Four-Port Copper Bypass Type 2 card (NIC-1-001G-4TX-BP)
 
Port
Description
L0, W0, L1, W1
Provides access to 10/100/1000 Base-T
 
LED
Type 1 definitions
Type 2 definitions
LINK/ACT
Link = Green
Activity = Blinks green
Link = Green
Activity = Blinks green
BYP/DISC. SPD
1000 Mbps = Yellow
100 Mbps = Green
10 Mbps = Off
Bypass = Blinks green
Disconnect = Blinks yellow
SPD
1000 Mbps = Orange
100 Mbps = Green
10 Mbps = Off
BYP1, BYP0
Disconnect = Yellow
Bypass = Green
Normal = Off
 
Specification
Descriptions
Connectors
Four shielded RJ-45
Cables and operating distance
10-Base-T Category 3, 4, or 5 maximum 50 m*
100-Base-TX Category 5 maximum 50 m*
1000-Base-T Category 5E maximum 50 m*
*Theoretical distance is defined as half a distance as stated by the IEEE 802.3 standard.
Two-Port 1-GbE Fiber SX card
Two types of Two-Port 1-GbE Fiber SX cards can be installed in the 1U SteelHead 3070 and the 2U SteelHead 5070, SteelHead 7070, and Interceptor 9600 appliances.
Type 2 cards are supported on the following software versions:
SteelHead versions: 8.6.0, 9.0.0, 9.1.0 and 9.2.0
Interceptor versions: 4.5.3, 5.5.0, and 5.0.1
The physical ports on the NICs are mapped in proximity to the PCI bus edge connector. The port closest to the edge connector is L0, then W0, L1, followed by W1.
Figure B‑3. Two-Port 1-GbE Fiber SX Type 1 card (NIC-1-001G-2SX-BP)
Figure B‑4. Two-Port 1-GbE Fiber SX Type 2 card (NIC-1-001G-2SX-BP)
 
Port
Description
P0, P1
TX and RX provides access to 1000 Base-SX
 
LED
Type 1 definition
Type 2 definition
ACT
Activity = Blinks green
Activity = Blinks yellow
BYP/DSC.
Normal = Off
Disconnect = Yellow
Bypass = Green
Normal = Off
Disconnect = Red
Bypass = Green
LNK
Link = Yellow
Link: Green
No link = Off
 
Specification
Description
Connectors
Two small form factor (SFF) LC fiber connectors
Cables and operating distance
Multimode fiber = 137 m maximum at 62.5 micrometers cable (half of theoretical distance of IEEE 802.3 standard)
Four-Port 1-GbE Fiber SX card
There are 2 types of Four-Port 1-GbE cards available. Both types can be installed in the 1U SteelHead 3070 and the 2U SteelHead 5070, SteelHead 7070, and Interceptor 9600 appliances.
Type 2 cards are supported on the following software versions:
SteelHead versions: 8.6.0, 9.0.0, 9.1.0 and 9.2.0
Interceptor versions: 4.5.3, 5.5.0, and 5.0.1
The physical ports on the NICs are mapped in proximity to the PCI bus edge connector. The port closest to the edge connector is L0, then W0, L1, followed by W1.
Figure B‑5. Four-Port 1-GbE Fiber SX Type 1 card (NIC-1-001G-4SX-BP)
Figure B‑6. Four-Port 1-GbE Fiber SX Type 2 card (NIC-1-001G-4SX-BP)
 
Port
Description
L0, W0, L1, W1
TX and RX provides access to 1000 Base-SX
 
LED
Type 1 definitions
Type 2 definitions
LNK
Link = Green
LNK/ACT
Link = Green
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
Normal = Off
Disconnect = Yellow
Bypass = Green
ACT
On = Blinks orange
 
Specification
Definition
Connectors
4 small form factor (SFF) LC fiber connectors
Cables and operating distance
Multimode fiber = 137 m maximum at 62.5 micrometers cable (half of theoretical distance of IEEE 802.3 standard)
Two-Port 1-GbE Fiber LX card
Figure B‑7. Two-Port 1-GbE Fiber LX (NIC-1-001G-2LX-BP)
 
Port
Description
P0, P1
TX and RX provides access to 1000 Base-LX
 
LED
Definition
P0 ACT, P1 ACT
Activity status of the port
LNK
Link = Yellow
ACT
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specification
Description
Connectors
Two small form factor (SFF) LC fiber connectors
Cables and Operating distance
Single-mode fiber: 9 micrometers
2500 m maximum at 9 micrometers*
* Theoretical distance is defined as half a distance as stated by the IEEE 802.3 standard.
Four-Port 1-GbE Fiber LX card
Figure B‑8. 4-Port 1-GbE Fiber LX (NIC-1-001G-4LX-BP)
 
Port
Description
L0, W0, L1, W1
TX and RX provides access to 1000 Base-LX
 
LED
Definition
LINK/ACT
Link = Green
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specifications
Description
Connectors
Four small form factor (SFF) LC fiber connectors
Cables and operating distance
Single-mode fiber: 9 micrometers
2500 m maximum at 9 micrometers*
* Theoretical distance is defined as half a distance as stated by the IEEE 802.3 standard.
Two-Port 10-GbE Fiber SR card
Figure B‑9. Two-Port 10-GbE Fiber SR (NIC-1-010G-2SR-BP)
 
Port
Description
L0, W0
TX and RX provides access to 10GBase-SR
 
LED
Definition
LNK
Link = Yellow
ACT
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specification
Definition
Connectors
Two small form factor (SFF) LC fiber connectors
Cables and operating distance
Multimode fiber:
13 m using 62.5 micrometers, 160 MHz km
16.5 m using 62.5 micrometers, (OM1) 200 MHz km
33 m using 50 micrometers, 400 MHz km
41 m using 50 micrometers, (OM2) 500 MHz km
150m using 50 micrometers, (OM3) 2000 MHz km
All distances are the theoretical distance, which is defined as half a distance as specified in the optical transceiver.
Two-Port 10-GbE Fiber LR card
Figure B‑10. Two-Port 10-GbE Fiber LR (NIC-1-010G-2LR-BP)
 
Port
Description
L0, W0
TX and RX provides access to 10GBase-LR
 
LED
Definition
LNK
Link = Yellow
ACT
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specification
Definition
Connectors
Two small form factor (SFF) LC fiber connectors
Cables and operating distance
Single-mode fiber: 9 u, Max 5 km *
* Theoretical distance is defined as half a distance as specified in the optical transceiver.
Two-Port 40-GbE Fiber SR4 card
Figure 6‑16. Two-Port 40-GbE Fiber SR4 Card (NIC-1-040G-2SR4-BP)
 
Port
Description
P0, P1
P0 and P1 provide access to 40GBase-SR
 
LED
Definition
LINK/Activity
Link = Green
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specification
Definition
Connectors
Four small form factor MTP-MTP fiber connectors
Cables and operating distance
Multimode Fiber
0.5 to 50m using 50 micrometers, (OM3) 1500 MHz Km
0.5 to 75 m using 50 micrometers, (OM4) 3500 MHz Km
All distances are defined as half a distance as specified in the optical transceiver.
Two-Port 40-GbE Fiber LR4 card
Figure 6‑17. Two-Port 40 GbE Fiber LR4 Card (NIC-1-040G-2LR4-BP)
 
Port
Description
P0, P1
P0 and P1 provide access to 40GBase-LR4
 
LED
Definition
LINK/Activity
Link = Green
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specification
Definition
Connectors
Four small form factor (SFF) LC fiber connectors
Cables and operating distance
5km using SMF-28 cables
Distance is defined as half of the distance as specified in the optical transceiver.
Four-Port 1-GbE Copper Base-T card
Figure 6‑18. Four-Port 1-GbE Copper Base-T (NIC-1-001G-4TX)
 
Port
Description
P0, P1, P2, P3
Provides access to 10/100/1000 Base-TX
 
LED
Description
Link/Activity (LED1)
Link= Green
Activity = Blinks green
Speed (LED2)
1 G = Yellow
100 M = Green
10 M= Off
 
 
 
Connectors
Four shielded RJ-45
Cables and operating distance
10 Base-T Category 3, 4, or 5 maximum 100 m
100 Base-TX Category 5 maximum 100 m
1000 Base-T Category 5E maximum 100 m
Two-Port 10-GbE Copper card
Figure B‑11. Two-Port 10-GbE Copper (NIC-1-010G-2TX)
 
Port
Description
P0, P1
Provides access to 100/1000/10G Base-T
 
LED
Description
10G=GRN
1G=YLW
(LED1)
10 G = Green
1 G = Yellow
100 M = Off
LINK/ACT=GRN (LED2)
Link = Green
Activity = Blinks green
 
Specification
Description
Connectors
Two shielded RJ-45
Cables and operating distance
100-Base-TX Category 5 maximum 100 m
1000-Base-T Category 5E maximum 100 m
10G-Base-T Category 6A maximum 100 m
Four-Port 10-GbE Copper card
Figure B‑12. Four-Port 10-GbE Copper (NIC-1-010G-4TX)
 
Port
Description
P0, P1, P2, P3
Provides access to 100/1000/10G Base-T
 
LED
Description
10G=GRN
1G=YLW
(LED1)
10 G = Green
1 G = Yellow
100 M = Off
LINK/ACT=GRN (LED2)
Link = Green
Activity = Blinks green
 
Specification
Description
Connectors
Four shielded RJ-45
Cables and operating distance
100-Base-TX Category 5 maximum 100 m
1000-Base-T Category 5E maximum 100 m
10G-Base-T Category 6A maximum 100 m
Four-Port 1-GbE Fiber/Copper SFP card
Figure B‑13. Four-Port 1-GbE Fiber/Copper SFP Card (NIC-1-001G-4SFP)
 
Port
Description
P0, P1, P2, P3
Provides access to 1000 Base-TX, LX, or SX
 
LED
Description
LNK
Yellow
LNK/ACT
Link Green
Activity: Blinks green
 
Specification
Description
Connectors
Four small form factor pluggable (SFP) cage
Cables and operating distances
SFP 1GBase-Copper module
1000 Base-T Category 5E maximum 100 m
SFP 1GBase-SX module
Multimode Fiber:
220 m using 62.5 micrometers
550 m using 50 micrometers
SFP 1GBase-LX module
Single-mode Fiber: 5000 m using 9 micrometers
Multimode Fiber: 550 m using 50 micrometers
550 m using 62.5 micrometers
 
Supported SFPs
Manufacturing part #
Orderable part #
SFP 1 GbE Copper module
410-00138-01
TRC-1-SFP-TX-C
SFP 1 GbE SX
410-00139-01
TRC-1-SFP-SX
SFP 1 GbE LX
410-00140-01
TRC-1-SFP-LX
Two-Port 4/8/16-GbE FC HBA (SAN)
Figure 6‑19. Two-Port fiber channel 4/8/16 GbE host bus adapter (SAN) Card (NIC-1-HBA-2FC)
 
Port
Description
Ports A, B
Provide access to 40GBase-LR4
Dimensions
6.60” x 2.71” (167.64 mm x 68.91mm)
Optical Data Rates
14.025 GbE (1600 Mbps)
8.5 GbE (800 Mbps)
4.25 GbE (400 Mbps, auto-detected)
Data Transfer Rates
Supports 16 GFC, 8 GFC, and 4 GFC link speeds, automatically negotiated
 
LED
Definition
Link/Activity
Link/Activity = Blinks yellow
Firmware operation = Green
 
Specification
Definition
Connectors
LC type connectors
Cables and operating distance
100 m at 16-GbE on 50/125 micrometers OM3 MMF
125 m at 16-GbE on 50/125 micrometers OM4 MMF
15 m at 16-GbE on 62.5/125 micrometers OM1 MMF
35 m at 16-GbE on 50/125 micrometers OM2 MMF, Operating at 16Gb
Distance is defined as half of the distance as specified in the optical transceiver.
Two-Port 10-GbE Fiber SFP+ card
Figure B‑14. Two-Port 10-GbE Fiber SFP+ (NIC-1-010G-2SFPP)
 
Port
Description
P0, P1, P2, P3
Provides access to 10-GbE-Base-SR, LR, or DAC
 
LED
Description
LNK P0, LNK P1
Green
LNK/ACT
Link= Green
Activity = Blinks green
 
Specification
Description
Connectors
Two small form factor pluggable (SFP+) cage
Cables and operating distance for the supported SFPs
SFP+ 10 GbE Direct Attached Cable
10-G Passive Direct Attach Cable, up to 10 meters
SFP+ 10GBase-SR module 62.5 micrometers
160 MHz/km 26 m
62.5 micrometers, (OM1) 200 MHz/km 33 m
50 micrometers, 400 MHz/km 66 m
50 micrometers, (OM2) 500 MHz/km 82 m
50 micrometers, (OM3) 2000 MHz/km 300 m
SFP+ 10GBase-LR module
Single-Mode = 10000 m at 9 micrometers
SFPs
Manufacturing part #
Orderable part #
SFP+ 10 GbE DAC
410-00140-01
TRC-1-SFPP-DAC-C
SFP+ 10 GbE SR
410-00143-01
TRC-1-SFPP-SR
SFP+ 10 GbE LR
410-00144-01
TRC-1-SFPP-LR
Four-Port 10-GbE Fiber SFP+ card
Figure B‑15. Four-Port 10-GbE Fiber SFP+ Card (NIC-1-010G-4SFPP)
 
LED
Description
Speed
Blue = 10 GbE
Yellow = 1 GbE
Link/Activity
Link = Green
Activity = Blinks green
 
Specification
Description
Connectors
Two small form factor pluggable (SFP+) cage
Cables and operating distance for the supported SFPs
SFP+ 10 GbE Direct Attached Cable
10-G Passive Direct Attach Cable, up to 10 meters
SFP+ 10GBase-SR module 62.5 micrometers
160 MHz/km 26 m
62.5 micrometers, (OM1) 200 MHz/km 33 m
50 micrometers, 400 MHz/km 66 m
50 micrometers, (OM2) 500 MHz/km 82 m
50 micrometers, (OM3) 2000 MHz/km 300 m
SFP+ 10GBase-LR module
Single-Mode: 10000 m at 9 micrometers
SFPs
Manufacturing part #
Orderable part #
SFP+ 10 GbE DAC
410-00140-01
TRC-1-SFPP-DAC-C
SFP+ 10-GbE SR
410-00143-01
TRC-1-SFPP-SR
SFP+ 10-GbE LR
410-00144-01
TRC-1-SFPP-LR
Two-Port 40-GbE Time Stamp card
Figure B‑16. Two-Port 40-GbE QSFP+ Time Stamp Card (NIC-1-040G-2QSFP-TS)
 
Network Interface
Description
IEEE standardP0, P1
IEEE 802.3 40 Gbit/s Ethernet
Ports P0, P1
40Gb/s QSFP+ Interfaces
Data Rate
2 x 40 Gbit/s
Supported QSFP+ modules
40 G-Base-SR4 (850 nm)
40G-Base-LR4 (1310 nm)
 
Host Interface
Description
Physical bus connector
8-lane PCIe
PCIe bus type
1-8 lane PCIe Gen1/Gen2/Gen3
PCIe compliant
64 logical channels that can be connected to DMA or egressed to physical output ports.
 
LED
Description
Link/Activity
Link = Green
Activity = Orange
Panic = Red
Fail Safe
Press and hold on power on to load fallback firmware image.
 
Specification
Description
On Board Memory
8 GB (2x4GB 64 bit DDR3)
Timestamp Sync
1 pps connector located on printed circuit board, and connected to bracket with cable.
PCIe
Gen 3, 8 lanes
NIC
Size
Manufacturing part #
Orderable part #
Two-Port 40GbE Time Stamp Card
HHHL
410-00214-01
NIC-1-040G-2QSFP-TS
This NIC can house one of two QSFP plug-ins, the SR4 and the LR4.
QSFPs
Manufacturing part #
Orderable part #
Two-Port 40-GbE PCIe SR4
410-00147-01
TRC-1-QSFP-SR4
Two-Port 40-GbE PCIe LR4
410-00148-01
TRC-1-QSFP-LR4
Four-Port 10-GbE Fiber SR card
The four-port 10-GbE fiber SR NICs have a power connector cable attached that is not used in the Riverbed SteelHead platforms. The SteelHead systems are designed to fully power these NICs through the interface bus.
Figure 6‑20. Four-Port 10-GbE Fiber SR Card (NIC-1-010G-4SR-BP)
 
Port
Description
P0, P1, P2, P3
P0, P1, P2, P3 provide access to 10GBase-SR
 
LED
Definition
LINK/Activity
Link = Yellow on 1-GbE
Link = Green on 10-GbE
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specification
Definition
Connectors
Four small form factor (SFF) LC fiber connectors
Cables and operating distance
Multimode fiber:
62.5um, 160MHz/Km 13m
62.5um, (OM1)200MHz/Km 16.5m
50um, 400MHz/Km 33m
50um, (OM2)500 MHz/Km 41m
50um, (OM3)2000MHz/Km 150m
All distances are defined as half a distance as specified in the optical transceiver.
Four-Port 10-GbE Fiber LR card
The four-port 10-GbE fiber LR NICs have a power connector cable attached that is not used in the Riverbed SteelHead platforms. The SteelHead systems are designed to fully power these NICs through the interface bus.
Figure 6‑21. Four-Port 10-GbE Fiber LR Card (NIC-1-010G-4LR-BP)
 
Port
Description
P0, P1
P0, P1, P2, and P3 provide access to 10GBase-LR4
 
LED
Definition
LINK/Activity
Link = Yellow on 1-GbE
Link = Green on 10-GbE
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Green
 
Specification
Definition
Connectors
Four small form factor (SFF) LC fiber connectors
Cables and operating distance
Singlemode fiber
9u, maximum 5 km
All distances are defined as half a distance as specified in the optical transceiver.
Four-Port 10-GbE DAC redirector card
Figure 6‑22. Four-Port 10-GbE DAC Card (NIC-1-010G-DAC-BP)
 
Port
Description
P0, P1, P2, P3
P0, P1, P2, and P3 provide access to 10GBase-R
 
LED
Definition
LINK/Activity
Link = Blue
Activity = Blinks green
BYP/DSC
Normal = Off
Disconnect = Yellow
Bypass = Blinks green
 
Specification
Definition
Cables and operating distance
62.5um, 160MHz/Km 13m
62.5um, (OM1)200MHz/Km 16.5m
All distances are defined as half a distance as specified in the optical transceiver.
Four-Port 10-GbE Copper card
Figure 6‑23. Four-Port 10-GbE DAC Card (NIC-1-010G-4TX-BP)
 
Port
Description
P0, P1, P2, P3
P0, P1, P2, and P3 provide access to 10GBase-T
 
LEDs
Definition
LINK/Activity
Bypass/Disconnect
Activity
Two LEDs per port.
Left:
Link of 1 Gbps = Yellow
Link of 10Gbps = Green
Bypass = Blinks green
Disconnect = Blinks yellow
Right:
Activity (ACT) = Blinks Green
 
Specification
Definition
Cables and operating distance
100Base-Tx Category 5 maximum 50m1
1000Base-T Category 5E maximum 50m1
10GBase-T Category 6A,7 maximum 50m2
1. 1 Theoretical Distance – Defined as half a distance as stated by the IEEE 802.3-2005 standard
2. 2 Theoretical Distance – Defined as half a distance as stated by the IEEE 802.3an standard