SteelHead™ Deployment Guide : Optimization Techniques and Design Fundamentals : RiOS Data Store Synchronization
  
RiOS Data Store Synchronization
RiOS data store synchronization enables pairs of local SteelHeads to synchronize their data stores with each other, even while they are optimizing connections. RiOS data store synchronization is typically used to ensure that if a SteelHead fails, no loss of potential bandwidth savings occurs, because the data segments and references are on the other SteelHead. This section includes the following topics:
  • RiOS Data Store Synchronization Requirements
  • RiOS Data Store Error Alarms
  • You can use RiOS data store synchronization for physical in-path, virtual in-path, or out-of-path deployments. You enable synchronization on two SteelHeads, one as the synchronization the primary, and the other as the synchronization backup.
    The traffic for RiOS data store synchronization is transferred through either the SteelHead primary or auxiliary network interfaces, not the in-path interfaces.
    RiOS data store synchronization is a bidirectional operation between two SteelHeads, regardless of which deployment model you use. The SteelHead primary and backup designation is relevant only in the initial configuration, when the primary SteelHead RiOS data store essentially overwrites the backup SteelHead RiOS data store.
    SteelHead DX does not support RiOS data store synchronization.
    RiOS Data Store Synchronization Requirements
    The synchronization primary and its backup:
  • must have the same hardware model.
  • must be running the same version of RiOS.
  • do not have to be in the same physical location. If they are in different physical locations, they must be connected through a fast, reliable LAN connection with minimal latency.
  • Before you replace a synchronization primary for any reason, Riverbed recommends that you make the synchronization backup the new synchronization primary. This is so that the new primary (the former backup) can warm the new (replacement) SteelHead, ensuring that the most data is optimized and none is lost.
    RiOS Data Store Error Alarms
    You receive an email notification if an error occurs in the RiOS data store. The RiOS data store alarms are enabled by default.
    If the alarm was caused by an unintended change to the configuration, you can change the configuration to match the old RiOS data store settings again and then restart the optimization service (without clearing the data store) to reset the alarm. In certain situations you might need to clear the RiOS data store. Typical configuration changes that require a clear data store are changes to the data store encryption type or enabling the extended peer table.
    To clear the data store of data, restart the optimization service and click Clear the Data Store.
    For more information about the RiOS data store error alarm, see the SteelHead Management Console User’s Guide.