Managing Appliances with BMC
  
Managing Appliances with BMC
The xx80 and 9800 appliances include Baseboard Management Controller (BMC) support.
The BMC monitors the physical state of the appliance, it tracks system and network watchdogs, error logs, and sensors. The sensors of a BMC measure internal physical variables such as temperature, power settings, voltage levels, and fan speeds. You can configure email alerts in the web interface for activity detected outside specified limits. The BMC also allows you to start, restart, and turn off the appliance remotely.
The desktop x80 and 1U xx80 appliances use the primary port as the BMC port for communication. The AUX port does not support BMC communication on these appliances.
The 2U xx80 and 9800 appliances use the RJ45 port (located above the USB ports) as the BMC port for communication. The PRI/AUX ports do not support BMC communication on these appliances.
Logging in to the BMC
The BMC provides a web interface for monitoring and management. You can access this interface through HTTPS.
This chapter describes some of the key features of the BMC. For complete details about each page, log in to the BMC and click the Help icon in the upper-right corner.
1. Connect to the appropriate port for BMC communication. For appliance port locations, see Reference: Appliance Lights, Ports, and Specifications.
For Desktop x80 and 3080 appliances, connect to the primary port. For the location of the primary port on these appliances, see Front panel Desktop x80 and Front panel 3080 appliance.
For 2U xx80 and 9800 appliances, connect to the BMC (RJ45) port, see Back panel 2U 9800 appliances.
2. In a web browser, enter the IP address.
To display the BMC IP address for a SteelHead, from the command line use the show remote ip command.
3. If the connection isn’t trusted (possibly using a self-signed certificate), you are prompted to add and confirm a security exception.
4. When prompted, log in to the web interface. The default username is admin; the default password is password.
Dashboard
After you log in, the BMC interface appears and displays the Dashboard.
Viewing sensor information
The Sensor Reading page displays all critical sensors, discrete sensor states, normal sensors, and disabled sensors. You can view sensor details and change sensor threshold (if supported on the sensor).
The Sensor Reading page refreshes automatically with live data retrieved from the database. There might be some delay in retrieving the live data.
Sensor Reading page
To view sensor details and events and changing threshold settings
1. Select the sensor name to display the Sensor detail page. This page displays information, events, and thresholds. The graph is a live representation of the sensor readings.
Sensor details page
2. Mouse over the graph point to view the sensor information.
3. Scroll to Sensor Events to view all the event entries for this sensor in a reverse chronological order.
4. To change sensor thresholds (if supported on the sensor), click Change Thresholds to display the Thresholds Sensor page.
The Change Thresholds button is enabled only for administrator or operator privilege users. For other users, this option is disabled.
Changing sensor thresholds
5. Enter the desired threshold values and click Save.
Viewing the field replaceable units
The Field Replaceable Units (FRU) Information page displays:
Available FRU devicesSelect the FRU ID to display detailed information.
Chassis informationDisplays the format version, type, part number, serial number, and add-ons.
Board informationDisplays the format version, language, manufacturer date and time, manufacturer, product name, serial number, part number, FRU ID, and add-ons.
Product InformationDisplays format version, language, manufacturer, name, version, serial number, asset tag, file ID, and add-ons.
FRU Information page
Viewing logs and reports
Choose Logs & Reports > <report name> to view IPMI logs, event logs, and system logs:
IPMI Event Log pageDisplays a list of events from the sensor event logs for the appliance. You can filter by date, event type, and sensor component. You can clear and download event logs. Mouse over the graph to view the number of events by date. You can also select between BMC or Client Time zone. Click a record to see the details of that entry. Clearing event logs deletes all existing records for all sensors.
IPMI Event Log page
System logsDisplays system logs of system events for this device (if the options have been configured). To configure system events, choose Settings > Log Settings > Advanced Log Settings. Filtering options are also available for this and all logs in this section.
System Log page
Audit logsDisplays audit events for this device (if configured). To configure audit logs, choose Settings > Log Settings > Advanced Log Settings.
Audit Logs page
Viewing and modifying settings
You can view and modify these settings on the Settings page:
External User ServicesModify LDAP/Edirectory, Active directory, and RADIUS settings.
KVM Mouse SettingAs administrator, modify the mouse modes: Relative mouse mode, Absolute mouse mode, and Other mouse mode.
Log SettingsModify advanced log settings to view all system events and filter entries based on their classification levels.
Media Redirection SettingsModify general settings, Vmedia instance settings, and remote session settings.
Network SettingsModify network IP settings, network link configuration, DNS configuration, and sideband interface settings.
PAM Order SettingsModify the PAM (Pluggable Authentication Modules) order for user authentication into the BMC.
Platform Event FilterModify event filters, alert policies, and LAN destinations.
ServicesModify web, KVM, CD-media, FD-media, and HD-media settings.
SMTP SettingsModify SMTP settings, including the LAN interface and email ID.
SSL SettingsView the SSL certificate, generate the SSL certificate, and upload the SSL certificate.
System FirewallView and modify existing firewall settings and add a firewall.
User ManagementConfigure user management settings.
Video RecordingConfigure SDL Settings and JAVA SOL. You must enable Remote Media Support before you configure video recording settings.
Remotely controlling the appliance
You can launch a remote serial-over-LAN session for the appliance from the Remote Control page.
Choose Remote Control, and click Activate to launch a remote session for the appliance.
Remote Control page
Enabling image redirection
Choose Image Redirection to emulate CD/DVD/HDD images in the network to host as media through BMC. Supported media types are:
CD/DVD format: ISO9660, UDF(v1.02~v2.60).
CD/DVD media file type: (*.iso), (*.nrg).
HDD media file type: (*.img), (*.ima).
To configure the image, you must enable Remote Media support in Settings > Media Redirection > General Settings. To start redirection or clear an image, you must have administrator privileges.
The table shows remote images available to the BMC. You can start redirection or clear the images from here. Only Single image can be configured for each image type, depending on your configuration.
To start and stop image redirection
1. Click Play to redirect the selected image.
2. Click Stop to stop the remote image redirection.
To clear an image from the BMC
Click Clear to remove the selected image from the BMC.
Powering and resetting the appliance using the BMC
You can reboot, restart, or power on the appliance from the BMC. The page also shows the current status of the appliance.
1. Choose Power Control.
2. Select one of the following power control options:
Power OffImmediately power off the appliance.
Power OnPowers off and then reboots the system (cold boot).
Power CycleReboots the appliance without powering off (warm boot).
Hard ResetInitiates operating system shutdown prior to the shutdown.
ACPI ShutdownSends Advanced Configuration and Power Interface (ACPI) shutdown signal to the virtual machine, which has the same effect as if you had pressed the power button.
3. Click Perform Action.
Maintaining the BMC
You can perform these maintenance tasks:
Backup ConfigurationYou can check the component before performing a backup. By default, IPMI configurations are selected automatically when you select the Network and Services box. You can save the backup config file to a location of your choice.
BMC RecoveryYou can perform a BMC recovery with these options: force a recovery on the next reboot; set the number of retries to reset the BMC (from 1 to 5); set the number of retries (from 1 to 5) to recover a firmware image during the recovery process; set the address of the server where the firmware image will be stored; set the image name.
Firmware Image LocationSet the protocol to be used to transfer the firmware image onto the BMC: Web upload during flash or TFTP server.
Firmware InformationDisplays the firmware image date, time, and version.
Firmware UpdatePerform a firmware image update.
HPM Firmware UpdatePerform a Hardware Platform Management (HPM) firmware image update.
Preserve ConfigurationCheck the configuration settings to be preserved when a restore configuration operation is performed.
Restore ConfigurationNavigate to a previously saved configuration file to be restored.
Restore Factory DefaultsSet configurations to be preserved during a restore operation.
System AdministratorView username and password, enable or disable user access, and change the password.
Signing out of the BMC session
1. Choose Sign out to display the confirmation pop-up window.
2. Click OK to end the session.