Reference | LED/button | Description |
1 | Power On/Off Button and Integrated LED | On = Green (System is turned on.) Sleep State = Green (System is in S1 or S3 sleep state.) Off = No light (Power is off.) |
2 | IPMI Warning LED | The IPMI Warning LED shows the current health of the server system. Normal = Green (No failures) Degraded/Warning = Amber (Indicates fan failure, high temperature, over voltage, or power supply failure.) Critical = Blinking Amber and Green (Indicates a problem that needs attention, such as optimization service down, no license, or in_path is not enabled for optimization service.) |
3 | ID LED | On = Blue (System identified remotely on the server.) Off = Off (System not identified.) |
4 | Reset Button | Press to reboot the appliance. |
5 | System ID Button | Press the system ID button when the system AC (Alternating Current) is on. The system ID LED indicates the system is identified with a blue light. Users from a remote site can activate the ID LED by inputting commands in IPMI. For details, contact Support at https://support.riverbed.com. |
6, 7 | USB Ports v2.0 | |
8 | HDD/SSD LEDs | Activity LED (lower light) Link = Green (Drive present, with no activity.) Activity = Blinks green (Drive present, with activity.) Status LED (upper light) Failed Disk = Solid Red |
LED/button | Description |
ID LED/Button | On = Blue (System identified remotely on the server.) Off = Off (System not identified.) Press the system ID button when the system AC (Alternating Current) is on. The system ID LED indicates the system is identified with a blue light. Users from a remote site can activate the ID LED by inputting commands in IPMI. For details, contact Support at https://support.riverbed.com. |
Primary and AUX Port LEDs | Left LED Link = Green Activity = Blinks green No Link = Off Right LED 10 Mbps = Off 100 Mbps = Green 1000 Mbps = Amber |
Four-Port 1 GbE Copper Bypass Card LEDs (preinstalled) | Link/Activity LED Link = Green Activity = Blinks green Speed/Bypass/Disconnect LED 1000 Mbps = Yellow 100 Mbps = Green 10 Mbps = Off Bypass = Blinks green Disconnect = Blinks yellow |
Power Supply LEDs | Power On and Healthy = Green Standby = Blinks green Power Off = Off Unplugged or power lost but second power supply has power = Amber (for about 5 seconds) then turns Off Power on with warning = Blinks amber (indicates high temperature, high power, high current, or slow fan) |
Specification | 5080 | 7080 |
Form factor | 2U | 2U |
Memory | 32 GB (4 x 8 GB) | B010 = 64 GB (8 x 8 GB) B020 = 96 GB (12 x 8 GB) B030 = 192 GB (12 x1 6 GB) |
HDD | 2 x 1 TB | 2 x 1 TB |
SSD | 6 x 240 GB | B010 = 6 x 480 GB B020 = 8 x 480 GB B030 = 8 x 960 GB |
Data store | 1.4 TB | B010 = 2.8 TB B020 = 3.8 TB B030 = 7.6 TB |
Dimensions (LxWxH) | 27.56 x 17.32 x 3.43 in. (700 x 440 x 87 mm) | 27.56 x 17.32 x 3.43 in. (700 x 440 x 87 mm) |
Weight (without packaging) | 51 lb (23 kg) | 51 lb (23 kg) |
Voltage | 100-127 V, 200-240 V | 100-127 V, 200-240 V |
PSU | 2 x 770 W 100-127 VAC/10 A, 50/60 Hz 200-240 VAC/5 A, 50/60 Hz | 2 x 770 W 100-127 VAC/10 A, 50/60 Hz 200-240 VAC/5 A, 50/60 Hz |
PCI slots | 6 | 6 |
Included bypass ports/max # ports | 4/20 | 4/20 |
System | CX 5080 | CX 7080 | CX 7080 | |||
Configuration | B010 | B010, B020 | B030 | |||
PSU type | 2 x 770 W | 2 x 770 W | 2 x 770 W | |||
AC input | 120 V | 230 V | 120 V | 230 V | 120 V | 230 V |
Max. amps. | 3.2 A | 1.7 A | 3.9 A | 2.0 A | 5.0 A | 2.6 A |
Max. watts | 372 W | 363 W | 467 W | 455 W | 598 W | 574 W |
Typical watts | 298 W | 290 W | 374 W | 364 W | 478 W | 459 W |
Max. volt-ampere | 383 VA | 395 VA | 477 VA | 473 VA | 604 VA | 592 VA |
Power factor | 97 W/VA | 92 W/VA | 98 W/VA | 96 W/VA | 99 W/VA | 97 W/VA |
BTU (typical) | 1015 BTU | 991 BTU | 1275 BTU | 1240 BTU | 1632 BTU | 1566 BTU |
Specification | 5080 | 7080 |
Operating acoustic | 56 dB (typical) | 56 dB (typical) |
Temperature (operating) | 32° to 104°F (0°- 40°C) | 32° to 104°F (0°- 40°C) |
Temperature (storage) | -40° to 140°F (-40°- 60°C) | 40° to 140°F (-40°- 60°C) |
Relative humidity | 40% to 90%, noncondensing at 40°C | 40% to 90%, noncondensing at 40°C |
Reference | LED/button | Description |
1 | Power On/Off Button and Integrated LED | On = Green (System is turned on.) Sleep State = Green (System is in S1 or S3 sleep state.) Off = No light (Power is off.) |
2 | IPMI Warning LED | The IPMI Warning LED shows the current health of the server system. Normal = Green (No failures) Degraded/Warning = Amber (Indicates fan failure, high temperature, over voltage, or power supply failure.) Critical = Blinking Amber and Green (Indicates a problem that needs attention, such as optimization service down, no license, or in_path is not enabled for optimization service.) |
3 | ID LED | On = Blue (System identified remotely on the server.) Off = Off (System not identified.) |
4 | Reset Button | Press to reboot the appliance. |
5 | System ID Button | Press the system ID button when the system AC (Alternating Current) is on. The system ID LED indicates the system is identified with a blue light. Users from a remote site can activate the ID LED by inputting commands in IPMI. For details, contact Support at https://support.riverbed.com. |
6, 7 | USB Ports v2.0 | |
8 | HDD/SSD LEDs | Activity LED (lower light) Link = Green (Drive present, with no activity.) Activity = Blinks green (Drive present, with activity.) Status LED (upper light) Failed Disk = Solid Red |
LED/button | Description |
ID LED/Button | On = Blue (System identified remotely on the server.) Off = Off (System not identified.) Press the system ID button when the system AC (Alternating Current) is on. The system ID LED indicates the system is identified with a blue light. Users from a remote site can activate the ID LED by inputting commands in IPMI. For details, contact Support at https://support.riverbed.com. |
Primary and AUX Port LEDs | Left LED Link = Green Activity = Blinks green No Link = Off Right LED 10 Mbps = Off 100 Mbps = Green 1000 Mbps = Amber |
Four-Port 1 GbE Copper Bypass Card LEDs (preinstalled) | Link/Activity LED Link = Green Activity = Blinks green Speed/Bypass/Disconnect LED 1000 Mbps = Yellow 100 Mbps = Green 10 Mbps = Off Bypass = Blinks green Disconnect = Blinks yellow |
Power Supply LEDs | Power On and Healthy = Green Standby = Blinks green Power Off = Off Unplugged or power lost but second power supply has power = Amber for about 5 seconds, and then turns Off Power on with warning = Blinks amber to indicate high temperature, high power, high current, or slow fan. |
LED or button | Description |
Power On/Off Button and Integrated LED | On = Blue (System is turned on.) Sleep State = Yellow (System is in S5 sleep state.) Off = No light (Power is off.) |
System LEDs | The combination of LED 1 and LED 2 defines the system state: LED 1 = Yellow, LED 2 = Yellow, System State = Critical LED 1 = Yellow, LED 2 = Green, System State =Degraded LED 1 = Green, LED 2 = Green, System State = Healthy LED 3 - Not used; default is off LED 4 - Not used; default is off |
Reset Button | Press to restore factory defaults. |
Console port | RJ45 port |
USB Ports v3.0 | 1 - USB Type A port 1 - USB Type C port |
Port 1 PRI = Primary port | Left LED Link = Green Activity = Blinks green Right LED 10 Mbps data rate = No light (with link on left LED) 100 Mbps data rate = Green 1000 Mbps data rate = Yellow |
Port 2 AUX = Auxiliary port | Left LED Link = Green Activity = Blinks green Right LED 10 Mbps data rate = No light (with link on left LED) 100 Mbps data rate = Green 1000 Mbps data rate = Yellow |
Ports 3-6 LAN/WAN ports | Left LED Link = Green Activity = Blinks green Bypass/Disconnect = Yellow Right LED 10 Mbps data rate = No light (with link on left LED) 100 Mbps data rate = Green 1000 Mbps/1 Gbps = Yellow |
Ports 7-8 (on-board) | Not used. |
LED/button | Description |
HDDs | Activity LED (upper light) Activity = Blinks green (drive present, with activity. Status LED (lower light) Failed Disk = Solid amber |
Power Supply LEDs | Power On and Healthy = Green Standby = 1 Hz blinks green Power Off = Off Unplugged or power lost but second power supply has power = Amber (for about 5 seconds) then turns Off Power on with warning = 1 Hz blinks amber (Indicates high temperature, high power, high current, or slow fan.) |
Specification | 1U 3080 |
Form factor | 1U rack mountable unit |
RAM | 24 GB |
HDD | 2 x 1 TB |
SSD | 1x 32 GB (for boot) |
Data store | 400 GB |
Dimensions (LxWxH) | 15.25 x 17.24 x1.73 in (387.35 x 483 x 44 mm) |
Weight (without packaging) | 27 lb (12.25 kg) |
Power (Typical) | 70 W |
BTU | 242 |
Voltage | 100-240 V |
PSU | 2 x hot-swappable/redundant, 550W W = 100-240 VAC/7.1/3.4A, 47-63 Hz |
PCIe slots | 1 FHFL (full height/full length) |
Bypass ports/maximum # | 4 (on-board) / 8 (with add-on card) |
System | 1U 3080 | |
PSU type | 2 x 550 W | |
AC input | 120 V | 240 V |
Max. watts | 88.7 W | 73.8 W |
Max. amps. | 0.9144 A | 0.488 A |
Power factor | 98.58 W/VA | 95.6 W/VA |
Max. volt-ampere | 89.97 VA | 77.19 VA |
Typical watts | 70.96 W | 59.04 W |
BTU (typical) | 241.97 BTU | 201.32 BTU |
Specification | CX 3080 |
Operating acoustic | 45 dB (typical) |
Temperature (operating) | 32° to 113°F (0° to 45°C) |
Temperature (storage) | -40° to 149°F (-40° to 65°C) |
Relative humidity | 20% to 80%, noncondensing (Operating) 10% to 95%, noncondensing (Storage) |
Front LEDs and buttons | Status |
Power Button LED | On = Blue (system is turned on) Sleep State = Yellow (system is in S5 sleep state) Off = No light (power is off) |
System LEDs | The combination of LED 1 and LED 2 defines the system state: LED 1 = Yellow, LED 2 = Yellow, System State = Critical LED 1 = Yellow, LED 2 = Green, System State =Degraded LED 1 = Green, LED 2 = Green, System State = Healthy LED 3 - Not used; default is off LED 4 - Not used; default is off |
Reset button | Restores system to factory defaults. |
Console port | RJ45 port |
USB ports v3.0 | 1 - USB Type A port 1 - USB Type C port |
Port 1 PRI | Left LED = Link/Bypass Link = On (Solid green) Activity =Blinks green Right LED= Speed 10 Mbps data rate = Off 100 Mbps data rate = Green 1000 Mbps data rate = Amber |
Port 2 AUX | Left LED = Link/Bypass Link = On (Solid green) Activity =Blinks green Right LED = Speed 10 Mbps data rate = Off 100 Mbps data rate = Green 1000 Mbps data rate = Amber |
Ports 3-6: LAN/WAN LEDs | Left LED Link = Green Activity = Blinks green Bypass/Disconnect = Yellow Right LED 10 Mbps data rate = No light (with link on left LED) 100 Mbps data rate = Green 1000 Mbps/1 Gbps = Yellow |
Ports 7-8 (on-board) | Not used. |
LED/button | Description |
Power Supply LEDs | Power On and Healthy = Green Standby = 1 Hz blinks green Power Off = Off Power lost but second power supply has power = Amber Power on with warning = 1 Hz blinks amber (indicates high temperature, high power, high current, or slow fan) |
Specification | 580 Desktop | 780 Desktop |
Power Watt (typical) | 37 W | 60 W |
BTU | 128 BTU | 205 BTU |
RAM | 16 GB | 16 GB |
HDD | 1 x 1 TB | 1 x 1 TB |
SSD | 1 x 32 GB (for boot) | 1 x 32 GB (for boot) |
Data store | 200 GB | 200 GB |
Dimensions (LxWxH) | 12.25 x 13.75 x 1.73 in. 311.15 x 349.25 x 44 mm | 12.25 x 13.75 x 1.73 in. 311.15 x 349.25 x 44 mm |
Weight (without packaging) | 6 lb (2.7 kg) | 6 lb (2.7 kg) |
Voltage frequency | 100-240 V/2.5 A 50/60 Hz | 100-240 V/2.5 A 50/60 Hz |
PSU | 1 x Internal, 200 W 100-240 VAC/2.5 A, 50/60 Hz | 1 x Internal, 200 W 100-240 VAC/2.5 A, 50/60 Hz |
Onboard bypass ports/max # ports | 4 | 4 |
System | CX 780 | |
PSU type | 2 x 550 W | |
AC input | 120 V | 240 V |
Max. watts | 75.1 W | 60.7 W |
Max. amps. | 0.7692 A | 0.39 A |
Power factor | 99 W/VA | 95.2 W/VA |
Max. volt-ampere | 75.85 VA | 63.76 VA |
Typical watts | 60.08 W | 48.56 W |
BTU (typical) | 204.87 BTU | 165.58 BTU |
System | CX 580 | |
PSU type | 2 x 550 W | |
AC input | 120 V | 240 V |
Max. watts | 46.8 W | 33.2 W |
Max. amps. | 0.486 A | 0.22 A |
Power factor | 97.71 W/VA | 94.8 W/VA |
Max. volt-ampere | 47.89 VA | 35.02 VA |
Typical watts | 37.44 W | 26.56 W |
BTU (typical) | 127.67 BTU | 90.56 BTU |
Specification | CX580 Desktop | CX780 Desktop |
Operating acoustic | 45 dBA Sound pressure (Typical) | 45 dBA Sound pressure (Typical) |
Temperature (operating) | 0° to 45° C 32° to 113° F | 0° to 45° C 32° to 113° F |
Temperature (storage) | -40° to 65° C -40° to 149° F | -40° to 65° C -40° to 149° F |
Relative humidity | 20% to 80% noncondensing | 20% to 80% noncondensing |
Storage humidity | 5% to 95% noncondensing | 5% to 95% noncondensing |