show storage luns
Displays details about all the LUNs configured for the current appliance, including:
Configuration status
LUN size and type
Prefetch setting
Mapped Edge appliances
Target and portal mapping
Session status
Prepopulation settings, status, progress, and schedules
Snapshot settings and schedules
MPIO policy settings
Syntax
show storage luns [block-disk | deactivated | edge-local | iscsi]
Parameters
block-disk
Limits the output to block-disk LUNs.
deactivated
Limits the output to deactivated LUNs.
edge-local
Limits the output to local edge LUNs.
iscsi
Limits the output to iSCSI LUNs.
Example
Edge_01 > show storage luns iscsi
Locally Assigned Serial: P3KRP4l4Q4m6
Configuration status : Ready
Alias : snapLun
LUN Size : 101.975 MB
LUN Type : iscsi
Online : yes
Failover Enabled : yes
Prefetch : Enabled
<partial output>
Product
SteelFusion Edge
Related Commands
show storage lun