show storage luns
Displays details about all the LUNs configured for the current appliance, including:
•Configuration status
•LUN size and type
•Prefetch setting
•Mapped Edge appliances
•Target and portal mapping
•Session status
•Prepopulation settings, status, progress, and schedules
•Snapshot settings and schedules
•MPIO policy settings
Syntax
show storage luns [block-disk | deactivated | edge-local | iscsi]
Parameters
block-disk | Limits the output to block-disk LUNs. |
deactivated | Limits the output to deactivated LUNs. |
edge-local | Limits the output to local edge LUNs. |
iscsi | Limits the output to iSCSI LUNs. |
Example
Edge_01 > show storage luns iscsi
Locally Assigned Serial: P3KRP4l4Q4m6
Configuration status : Ready
Alias : snapLun
LUN Size : 101.975 MB
LUN Type : iscsi
Online : yes
Failover Enabled : yes
Prefetch : Enabled
<partial output>
Product
SteelFusion Edge
Related Commands