storage iscsi array-settings
Adds or removes settings for the specified array type.
Syntax
[failover-peer] storage iscsi array-settings {add | remove} array-id <array-type>
Parameters
failover-peer
Performs the command on the failover peer of the current appliance. If the failover peer is unavailable, the changed configuration is automatically applied when the appliance returns to service.
You can run failover-peer commands only on a Core appliance in ActiveSolo failover state.
add
Adds a type of array.
remove
Removes a type of array.
array-id <array-type>
Specifies a type of array.
The format is <VendorID>:<ProductID>:<Revision>.
Example
Core_01 (config) # storage iscsi array-settings add array-id Nimble:Server:1.0
Service restart required for changes to take effect
Product
SteelFusion Core
Related Command
show storage iscsi