Restoring a system

Restore operations are performed using the mazu-sync command line utility. The restore operation copies system configuration information and traffic information from a customer-provided backup system.

Within the limitations listed in the Requirements topic, NetProfiler systems can be restored from backup copies as follows:

  • A backup copy from a Model xx80 hardware-based system can be used to restore a Model xx80 hardware-based system.

  • A backup copy from a cloud or virtual system can be used to restore a:

    • Cloud system

    • Virtual system

    • Model xx70 hardware-based system

    • Model xx80 hardware-based system

  • A backup copy from a Model xx70 hardware-based system can be used to restore a:

    • Model xx70 hardware-based system

    • Model xx80 hardware-based system

Before you begin

The NetProfiler must be configured for your installation before you run the mazu-sync command to restore it. This includes any applicable licenses.

Note that there are also configuration tasks that must be performed after the restore operation. These include:

  • Security settings - The settings on the Administration > Appliance Security > Security Compliance page are specific to the appliance and are not included in the backup image. This includes FIPS mode, Strict Security mode, the Shell Access setting, system user passwords, the Bootloader password and appliance access settings. These must be set for each appliance after restoring the image.

  • General Settings - Host name, IP address and other settings on the Administration > General Settings page should be reviewed after the restore operation.

Ensure that your system meets the requirements before beginning the restore operation.

Requirements for restoring a system

Restoring a Standard NetProfiler

Restoring an Enterprise NetProfiler

Backup