Specifying TACACS+ servers
You can specify multiple TACACS+ servers. NetProfiler tries to connect to each TACACS+ server in the order in which it is listed. It sends an authentication request to the first TACACS+ server it is able to connect to. The first TACACS+ server to provide a valid pass/fail response ends the search. Authentication requests include the information specified in the global TACACS+ settings. more
To specify a TACACS+ server that NetProfiler can use:
-
Go to the Configured Servers section of the TACACS+ tab of the Administration > Account Management > Remote Authentication page.
-
Enter the server information. This is normally provided by the TACACS+ server administrator.
The Client Port field specifies the TACACS+ protocol client port used on the Network Access Server (NAS). Leave this field empty unless the TACACS+ server administrator asks you to specify a port.
-
Select Enabled for the NetProfiler to use the server.
-
Click Add. This adds the server to the list.
-
Click the Test link in the Actions column for the entry to verify that NetProfiler can connect to the TACACS+ server. A message box reports the results of the connection attempt.
Server entries can be enabled, disabled, edited, deleted, and tested.