Configuring Edge : Configuring Edge high availability : Configuring ESXi dynamic discovery
  
Configuring ESXi dynamic discovery
In addition to performing the tasks for HA configuration, you must also configure the dynamic discovery address on the standby Edge.
1. From the Edge Management Console, choose Storage > Storage Edge Configuration.
2. Select the MPIO tab.
3. Take note of all the Local Interfaces for MPIO for the Edge.
4. Log in to the vSphere client and select the ESX host from the Inventory pane.
5. Select the Configuration tab, and select Storage Adapters in the Hardware pane.
6. Select the iSCSI initiator to configure and click Properties. The iSCSI Initiator Properties window appears.
7. Select the Dynamic Discovery tab.
8. Select the IP address from the Edge Storage Edge Configuration page.
9. Click Add to display the Add Send Target Server window.
10. Click Close.
High-availability considerations:
If the Edges are in a high-availability configuration, repeat Steps 1 to 10 for each ESX host.
After configuring ESXi dynamic discovery, ensure that the MPIO configuration for the active and standby Edges is displayed in the Dynamic Discovery Tab of both ESX hosts.