show admission
Displays admission control settings, including actual values of current connections and memory usage are displayed.
Syntax
show admission {control | cbad}
Parameters
| control  | Displays admission control settings. | 
| cbad | Displays the client-based autodiscovery (CBAD) table. | 
Usage
After performing a model upgrade, you must reapply admission control overrides relative to the default admission control values of the new model. For assistance with setting admission control overrides, please contact Support.
Example
amnesiac > show admission control
Enable Admission Control Override Settings: no
 
  Override Settings:
    Connection Enable:   6000
    Connection Cutoff:   6100
    Memory Enable:       5100 MB
    Memory Cutoff:       5200 MB
    Low Memory Ratio:    96%
 
  Current Settings:
    Connection Enable:   6000
    Connection Cutoff:   6100
    Memory Enable:       5100 MB
    Memory Cutoff:       5200 MB
    Low Memory Ratio:    96%
 
  Current State:
    Connections:         0
    Memory:              4042 MB
Product
SteelHead CX, SteelHead-v, SteelHead-c
Related Commands