show interceptor name all 
Displays status of redirect peers. Redirect peers include SteelHead Interceptors deployed in parallel to cover asymmetric routing, as well as a SteelHead Interceptor that functions as a failover interceptor. 
Syntax
show interceptor name all [configured] 
Parameters
| configured | Displays only a list of configured peers. | 
Usage
This command replaces the show redirect peers command.
Example
amnesiac > show interceptor name all
 
Peer                    Type Version       Backup                Last Reconnect 
----------------------- ---- ------------- --------------------- ---------------
perf1-int3              R    3.0.0-beta1   255.255.255.255:0     2011/03/18 12:1
7:29
                             Interface(s): 172.16.153.2:7860     Active      
                             Interface(s): 172.16.153.2:40269    Connected
perf1-int8              F    3.0.0-beta1   172.16.14.4:7860      2011/03/18 12:1
7:23
                             Interface(s): 172.16.14.2:40272     Active      
                                           172.16.121.2:40268    Connected
                                           172.16.14.2:40273     Connected
                                           172.16.121.2:40269    Connected
Type: 'R' = Redirect
      'F' = Failover
Product
Interceptor
Related Commands