alarm rate-limit
Sets the alarm rate-limit values. 
Syntax
alarm <type> rate-limit [email | snmp] term {long | medium | short} {count <value> | window <duration-seconds>}
Parameters
| <type> | See the alarm enable  command for a complete listing and description of alarm types. | 
| email | Sets rules for email. | 
| snmp | Sets rules for SNMP. | 
| term  | Sets the alarm event rate-limit term value. Valid choices are: •	long •	medium •	short | 
| count <value> | Sets the count value. The default values are 50 (long), 20 (medium), and 5 (short). | 
| window <duration-seconds> | Sets the duration of time, in seconds, that the window remains open. The default values are 604,800 (long), 86,400 (medium), and 3600 (short). | 
Usage
There are three term values: long, medium, and short. Each has a window, which is a number of seconds, and a maximum count. If, for any term value, the number of alarm events exceeds the maximum count during the window, the corresponding email/SNMP notifications are not sent.
Example
amnesiac (config) # alarm crl_error rate-limit email term short window 3500
Product
SCC, Interceptor, Client Accelerator, SteelHead, SteelHead-v, SteelHead-c
Related Commands