Configuration Mode Commands : Core iSCSI commands : storage snapshot storage-array modify host redundant-paths add rp-host
  
storage snapshot storage-array modify host redundant-paths add rp-host
Configures redundant paths to the specified snapshot host in case of failure.
Syntax
[failover-peer] storage snapshot storage-array modify host <hostname> redundant-paths add rp-host <rp-host> [rp-port <port>]
Parameters
failover-peer
Performs the command on the failover peer of the current appliance. If the failover peer is unavailable, the changed configuration is automatically applied when the appliance returns to service.
You can run failover-peer commands only on a Core appliance in ActiveSolo failover state.
<hostname>
Hostname of the storage array.
<rp-host>
Redundant hostname to add for the chosen storage array.
rp-port <port-number>
Specifies the redundant port number for the chosen storage array.
Example
amnesiac (config) # storage snapshot storage-array modify host sf-vva14 redundant-paths add rp-host sf-vva20 rp-port 90
Product
Core