Configuration Mode Commands : Core iSCSI commands : storage lun modify mpio path
  
storage lun modify mpio path
Configures MPIO paths for the LUN.
Syntax
[failover-peer] storage lun modify {alias <alias> | serial <serial>} mpio path {allow | exclude | preferred} path-id <path-id>
Parameters
failover-peer
Performs the command on the failover peer of the current appliance. If the failover peer is unavailable, the changed configuration is automatically applied when the appliance returns to service.
You can run failover-peer commands only on a Core appliance in ActiveSolo failover state.
alias <alias>
Specifies the LUN to be modified by its alias.
serial <serial>
Specifies the LUN to be modified by its serial number.
allow
Allows the specified path to be used in the MPIO configuration.
exclude
Excludes the specified path from being used in the MPIO configuration.
preferred
Configures the specified path as the preferred (principal) path for connections.
path-id <path-id>
Specifies the ID of the path to allow.
Example
Core_01 (config) # storage lun modify alias LUN4Edge2 mpio path allow path-id aux
 
Core_02 (config) # failover-peer storage lun modify alias LUN4Edge2 mpio path allow path-id aux
Product
Core