Configuration Mode Commands : Core iSCSI commands : storage lun modify map edge-id
  
storage lun modify map edge-id
Maps the LUN to the specified Edge.
Syntax
[failover-peer] storage lun modify {alias <alias> | serial <serial>} map edge-id <edge-self-identifier>
Parameters
failover-peer
Performs the command on the failover peer of the current appliance. If the failover peer is unavailable, the changed configuration is automatically applied when the appliance returns to service.
You can run failover-peer commands only on a Core appliance in ActiveSolo failover state.
alias <alias>
Specifies the LUN to be modified by its alias.
serial <serial>
Specifies the LUN to be modified by its serial number.
<edge-self-identifier>
Self-identifier of the Edge to which the LUN is to be added. Edge identifiers are case sensitive.
Example
Core_01 (config) # storage lun modify alias LUN4Edge2 map edge-id Edge2
 
Core_02 (config) # failover-peer storage lun modify alias LUN4Edge2 map edge-id Edge2
Product
Core