Configuration Mode Commands : Core iSCSI commands : storage lun add block-disk
  
storage lun add block-disk
Adds a block disk LUN for the Core. Note that you can add only discovered LUNs.
Syntax
[failover-peer] storage lun add block-disk serial <serial> alias <alias-name>
Parameters
failover-peer
Performs the command on the failover peer of the current appliance. If the failover peer is unavailable, the changed configuration is automatically applied when the appliance returns to service.
You can run failover-peer commands only on a Core appliance in ActiveSolo failover state.
serial <serial>
Specifies the LUN with its serial number.
alias <alias-name>
Specifies an alias name for the added LUN.
Example
Core_01 (config) # storage lun add block-disk serial 60a98132486e2f374f9f6f795f61565a alias LUN4Edge2
 
Core_02 (config) # failover-peer storage lun add block-disk serial 60a98132486e2f374f9f6f795f61565a alias LUN4Edge2
Product
Core