Configuration Mode Commands : Core iSCSI commands : edge id iscsi target modify-name
  
edge id iscsi target modify-name
Modifies the target name setting in the specified Edge.
Syntax
[failover-peer] edge id <id> iscsi target modify-name <target-name>
Parameters
failover-peer
Performs the command on the failover peer of the current appliance. If the failover peer is unavailable, the changed configuration is automatically applied when the appliance returns to service.
You can run failover-peer commands only on a Core appliance in ActiveSolo failover state.
<id>
Self-identifier of the Edge to which the configuration is to be pushed. This value is case sensitive and limited to the following characters: 0 to 9, a to z, A to Z, period (.), and hyphen (‑).
<target-name>
New value for the target name.
Example
Core_01 (config) # edge id Edge1 iscsi target modify-name iqn.2003-10.com.hoosgau:432716056
 
Core_02 (config) # failover-peer edge id Edge1 iscsi target modify-name iqn.2003-10.com.hoosgau:432716056
Product
Core