Configuration Mode Commands : Core iSCSI commands : edge id iscsi data-digest
  
edge id iscsi data-digest
Includes or excludes the data digest data in the iSCSI packet for the specified Edge.
Syntax
[failover-peer] edge id <id> iscsi data-digest {enable | disable}
Parameters
failover-peer
Performs the command on the failover peer of the current appliance. If the failover peer is unavailable, the changed configuration is automatically applied when the appliance returns to service.
You can run failover-peer commands only on a Core appliance in ActiveSolo failover state.
<id>
Self-identifier of the Edge to which the configuration is to be pushed. This value is case sensitive and limited to the following characters: 0 to 9, a to z, A to Z, period (.), and hyphen.
enable
Includes the data digest in the iSCSI packet in communications with the specified Edge.
disable
Excludes the data digest from the iSCSI packet in communications with the specified Edge.
Usage
All failover-peer edge commands enable you to configure an unavailable Core through its failover peer. When the intended Core becomes operational, the new configuration is added automatically.
Example
Core_01 (config) # edge id branch-009a iscsi data-digest disable
Core_01 (config) # edge id branch-009a iscsi data-digest enable
 
Core_02 (config) # failover-peer edge id Edge1 iscsi data-digest disable
Core_02 (config) # failover-peer edge id Edge1 iscsi data-digest enable
Product
Core