Configuration Mode Commands : Core commands : edge modify id clear-serial
  
edge modify id clear-serial
Clears the saved serial value for the Edge so that it can be replaced. This command is meant to be used while replacing an Edge in a non-HA configuration.
Syntax
[failover-peer] edge modify id <id> clear-serial
Parameters
failover-peer
Performs the command on the failover peer of the current appliance. If the failover peer is unavailable, the changed configuration is automatically applied when the appliance returns to service.
You can run failover-peer commands only on a Core appliance in ActiveSolo failover state.
<id>
Self-identifier of the Edge to which the configuration is to be pushed. This value is case sensitive and limited to the following characters: 0 to 9, a to z, A to Z, period (.), and hyphen (-).
Usage
You should run this command on the Core first, and then add the Core on the replacement Edge.
Example
Core_01 (config) # edge modify id Branch006a clear-serial
 
Core_02 (config) # failover-peer edge modify id Branch006a clear-serial
Product
Core