failover-peer | Performs the command on the failover peer of the current appliance. If the failover peer is unavailable, the changed configuration is automatically applied when the appliance returns to service. You can run failover-peer commands only on a Core appliance in ActiveSolo failover state. |
<id> | Self-identifier of the Edge to which the configuration is to be pushed. This value is case sensitive and limited to the following characters: 0 to 9, a to z, A to Z, period (.), and hyphen (‑). |
trigger-pct <percentage> | Triggers the alarm if the percentage of uncommitted data exceeds the specified threshold. The default threshold is 5 percent, which for a 4 TiB (1260-4) system is 200 GiB. |
repeat-pct <percentage> | Repeatedly triggers the alarm if the percentage of uncommitted data increases from a previous triggered value by more than the specified percentage. |
repeat-interval <interval> | Repeatedly triggers the uncommitted data alarm at periodic time intervals until the percentage of uncommitted data falls below the clear threshold limit. |