User Mode Commands : Displaying System Data : show admission
  
show admission
Displays admission control settings, including actual values of current connections and memory usage are displayed.
Syntax
show admission {control | cbad}
Parameters
control
Displays admission control settings.
cbad
Displays the client-based autodiscovery (CBAD) table.
Usage
After performing a model upgrade, you must reapply admission control overrides relative to the default admission control values of the new model. For assistance with setting admission control overrides, please contact Riverbed Support.
Example
amnesiac > show admission control
Enable Admission Control Override Settings: no
 
Override Settings:
Connection Enable: 6000
Connection Cutoff: 6100
Memory Enable: 5100 MB
Memory Cutoff: 5200 MB
Low Memory Ratio: 96%
 
Current Settings:
Connection Enable: 6000
Connection Cutoff: 6100
Memory Enable: 5100 MB
Memory Cutoff: 5200 MB
Low Memory Ratio: 96%
 
Current State:
Connections: 0
Memory: 4042 MB
Product
SteelHead CX, SteelHead EX, SteelHead-v, SteelHead-c
Related Commands
Configuration File Commands