SteelFusion Edge Technical Specifications : 2U SteelFusion Edge Specifications
  
2U SteelFusion Edge Specifications
This section describes the technical and environmental specifications for the SteelFusion Edge 3100, SteelFusion Edge 3200, and SteelFusion Edge 5100 appliances.
Technical Specifications
The following table summarizes the technical specifications for the appliances.
 
SteelFusion Edge 3100
SteelFusion Edge 3200
SteelFusion Edge 5100
Form Factor
2U
2U
2U
Dimensions (HxWxD)
3.24 x 17.56 x 25.27 in.
(87 x 446 x 644.4 mm)
3.24 x 17.56 x 25.27 in.
(87 x 446 x 644.4 mm)
3.24 x 17.56 x 25.27 in.
(87 x 446 x 644.4 mm)
Weight (without packaging)
48 lb (21.77 kg)
60 lb (27.22 kg)
60 lb (27.22 kg)
PCIe Slots
6 (4 for RiOS, 2 for hypervisor)
6 (4 for RiOS, 2 for hypervisor)
6 (4 for RiOS, 2 for hypervisor)
Bypass Ports/Max # Ports
2 /12
2 /12
2 /12
HDD
4 x 2TB
8 x 2TB
8 x 4TB
SSD
4 x 200 or 4 x 240GB
4 x 240 or 4 x 400GB
4 x 480GB
Data Store
280 GB
280 GB
320 GB
Blockstore
3500 GB
7400 GB
15200 GB
CPU
E5-2630v2 2.6GHz
6 cores
2 x E5-2630v2 2.6GHz
12 cores
2 x E5-2660v2 2.1GHz
20 cores
Environmental Specifications
The following table summarizes the environmental requirements for the 2U SteelFusion Edge appliances.
 
SteelFusion Edge 3100, 3200, and 5100
Operating Acoustic
56.4 dBA Sound pressure (Typical)
Temperature (Operating)
0º–40º C
32°–113º F
Temperature (Storage)
-40º–65º C
-40º–149º F
Relative Humidity
20%–80%
noncondensing
Storage Humidity
5%–95%
noncondensing
Operating Altitude
Up to 10,000 ft
Up to 3048 m