Riverbed Cloud Services : SteelHead-c models and required virtual machine resources
  
SteelHead-c models and required virtual machine resources
This section lists available SteelHead-c models, their supported maximum limits, and the minimum virtual machine resources required for each model.
Note: All CCX-SUB-PERF-TIER models must be manually deployed.
This table lists SteelHead-c models and their supported maximum limits.
SteelHead-c Model
Optimized Throughput Capacity
Maximum # of Connections
(All IaaS Vendors)
CCX-255U
2 Mbps
50
CCX-255L
6 Mbps
75
CCX-255M
6 Mbps
150
CCX-255H
6 Mbps
230
CCX-570L
6 Mbps
250
CCX-570M
10 Mbps
400
CCX-570H
10 Mbps
650
CCX-770L
10 Mbps
900
CCX-770M
10 Mbps
1500
CCX-1555L
50 Mbps
3000
CCX-1555M
50 Mbps
4500
CCX-3070H
150 Mbps
9000
CCX-SUB-PERF-TIER4
500 Mbps
1,000
CCX-SUB-PERF-TIER4-H
500 Mbps
30,000
CCX-SUB-PERF-TIER5
1 Gbps
1,000
CCX-SUB-PERF-TIER5-H*
1 Gbps
50,000
Each SteelHead-c instance requires at least two virtual disks. One disk stores the SteelHead-c configuration and management resources; the other disk serves as the data store. In AWS, virtual disk drives are referred to as Elastic Block Stores (EBS). Hard disk drives (HDD), also known as magnetic drives, can be used for most models, but solid state drives (SSDs) can provide higher performance.
Note: Riverbed recommends SSD drives for CCX-SUB-PERF-TIER5 and CCX-SUB-PERF-TIER5-H models.
Note: All CCX-SUB-PERF-TIER models running in Azure require multiple disks, each disk not to exceed 300 GB.
This table lists SteelHead-c models and the disk capacities needed for each.
SteelHead-c Model
Configuration and Management
Disk Size
Data Store Disk Size
CCX-255U through CCX-255H
38 GB
440 GB
CCX-570L through CCX- 555M
38 GB
460 GB
CCX-3070H
40 GB
400 GB
CCX-SUB-PERF-TIER4
CCX-SUB-PERF-TIER4-H
40 GB
960 GB
CCX-SUB-PERF-TIER5
CCX-SUB-PERF-TIER5-H
40 GB
2.4 TB
This table lists SteelHead-c models and the minimum instance type, or minimum virtual machine CPU and RAM, required to run each.
Note: Amazon Web Services (AWS) is phasing out support for m1.small instances. New m1.small instance creation is no longer supported in certain geographic zones. CCX-255 model SteelHead-c virtual appliances continue to use m1.small instances because an adequate newer equivalent instance type is not currently available. Therefore, creating new CCX-255 model SteelHead-c virtual appliances or restarting previously existing CCX-255 model SteelHead-c virtual appliances is not supported in certain geographic zones. Contact support@riverbed.com for details.
SteelHead-c Model
Azure Instance Type
EC2 Instance Type
ESX/ESXi VM
CCX-255U through CCX-255H
Standard_D1
m1.small
1 CPU/1000 MHz
2 GB RAM
CCX-570L through CCX-570H
Standard_D1
m3.large
1 CPU/1200 MHz
3 GB RAM
CCX-770L
CCX-770M
Medium/A2
m3.large
2 CPU/1200 MHz
3 GB RAM
CCX-1555L
CCX-1555M
Large/A3
m3.large
4 CPU/1200 MHz
8 GB RAM
CCX-3070H
Standard _D3
m3.xlarge
4 CPU/2.2 GHz
14 GB RAM
CCX-SUB-PERF-TIER4
CCX-SUB-PERF-TIER4-H
Standard_D14_v2
m4.4xlarge
N/A
CCX-SUB-PERF-TIER5
CCX-SUB-PERF-TIER5-H
Standard_D15_v2
m4.10x large