User Mode Commands : Displaying system data : show interfaces
  
show interfaces
Displays the running state settings and statistics.
Syntax
show interfaces {<interface-name> [arp | brief | configured | debug per [5min | hour | day | all | counter | counter-errors] | dhcp-lease | slaac]} | brief | configured | mtu-override
Parameters
<interface-name> | [arp | brief | configured | debug per | dhcp-lease | slaac]
Interface name. For example, aux, lan0_0, wan0_0, primary, in‑path0_0, or lo.
arp—Displays static and dynamic ARP entries for this interface.
brief—Displays the brief running state for this interface, including the power level if you have an optical card interface installed.
configured—Displays the configuration for this interface.
debug per—Displays the debugging statistics for this interface per a user-defined duration of time. To set the duration of time for NIC statistics collection, see the interface nic_stats configure duration command.
dhcp-lease—Displays the DHCP lease for this interface.
slaac—Displays the IPv6 Stateless Address Auto-Configuration (SLAAC) setting for this interface.
brief
Displays the brief running state for all interfaces.
configured
Displays the configuration settings for all interfaces.
mtu-override
Displays the MTU sync override setting.
Usage
The settings and statistics displayed vary when using DHCP.
If you are an admin user and you have an optical interface card (NIC-1-010G-2SR-BP [#410-00302-03] or NIC-1-010G-2LR-BP [#410-00301-03]) installed on the appliance, power-level readings are displayed with the show interface <interface-name> brief command. For example:
amnesiac # show interface wan4_0 brief​
Interface wan4_0 state​
Up: yes​
Interface type: ethernet​
Speed: 10000Mb/s​
Duplex: full​
MTU: 1500​
HW address: 00:0E:B6:AA:72:F0​
Link: yes​
Counters cleared date: 2019/12/16 00:44:33​
dev 0 port 1: TX output power=522 uW or -2.823295 dBm ​
dev 0 port 1: RX input power=447 uW or -3.496925 dBm
Example
amnesiac # show interfaces configured
Interface aux configuration
Enabled: yes
DHCP: no
Speed: auto
Duplex: auto
IP address: 10.0.190.139
Netmask: 255.255.0.0
MTU: 1500
Interface inpath0_0 configuration
Enabled: yes
DHCP: no
IP address: 10.11.192.139
Netmask: 255.255.0.0
MTU: 1500
Failure mode: Bypass <<fail-to-block or fail-to-bypass>>
Product
SCC, Interceptor, SteelHead CX, SteelHead-v, SteelHead-c, Client Accelerator
Related Commands
interface