protocol profiler ip-bypass force
Forces all bypass to be IP level. This feature is disabled by default. Auto-bypass must be enabled to force IP level bypass.
Syntax
[no] protocol profiler ip-bypass force
Parameters
None
Usage
When the feature sees a pattern of consistently bad performance for a server IP, it will bypass connections for a period of ten minutes.
Example
amnesiac (config) # protocol profiler ip-bypass force
You must restart the optimization service for your changes to take effect.
amnesiac (config) # show protocol profiler
Host Profiler status:
Enabled: No
Auto-bypass: Yes (but only once feature is enabled)
IP auto-bypass: Force (but only once auto-bypass is enabled)
Product
SteelHead
Related Commands