Configuration Mode Commands : SteelHead configuration commands : raid swraid set-rate
  
raid swraid set-rate
Sets the RAID rebuild rate.
Syntax
raid swraid set-rate <rate>
Parameters
<rate>
Rebuild rate as a number of megabytes or fast_rebuild, slow_rebuild, or normal.
Example
amnesiac (config) # raid swraid set-rate fast_rebuild
Product
SCC, Client Accelerator, SteelHead CX, SteelHead-v, SteelHead-c, SteelHead Interceptor
Related Commands
show raid info
Network test commands
This section describes the network testing commands. If you are experiencing network issues Riverbed Support will ask you to run network tests so that they can understand the state of the network.
With these tests common problems are easily identified and can be immediately addressed by the Riverbed support representative.