email notify passthrough rule enable
Enables or disables sending email reminders about pass-through rules and, optionally, sets the frequency of the email reminders.
Syntax
[no] email notify passthrough rule [notify-timer <frequency>] enable
Parameters
notify-timer <frequency> | Number of days to wait before receiving the next email reminder. By default, email reminders are sent every 15 days. |
Usage
Pass-through rules are often created as a solution for a temporary network issue. When the issue is resolved, it’s easy to forget that the rule is in use, which results in traffic not being optimized. With this command enabled, you’ll receive an email message reminding you that you have pass-through rules in use on your network, and asking you to check periodically whether you still need to use them. The email reminders help to identify any obsolete rules that you might want to delete to improve traffic optimization.
This command is enabled by default. To turn off the email reminders for all pass-through rules (in-path and load‑balancing), use the no command option without using the notify-timer keyword and specifying a frequency.
To enable email reminders, use this command along with the in‑path rule pass-through email-notify command for in‑path pass-through rules and the load balance rule pass email-notify command for load-balancing pass-through rules.
The email reminders are sent to the addresses shown in the event email recipients field of the show email command.
Example
amnesiac (config) # no email notify passthrough rule enable
Product
SCC, Interceptor, Client Accelerator, SteelHead CX, SteelHead-v, SteelHead-c
Related Commands