Configuration Mode Commands : SteelFusion Core iSCSI (block mode) commands : storage iscsi session header-digest enable
  
storage iscsi session header-digest enable
Includes the header digest in the iSCSI PDU for the current session; the running configuration does not change.
Syntax
[no] [failover-peer] storage iscsi session header-digest enable
Parameters
failover-peer
Performs the command on the failover peer of the current appliance. If the failover peer is unavailable, the changed configuration is automatically applied when the appliance returns to service.
You can run failover-peer commands only on a Core appliance in ActiveSolo failover state.
Usage
The header digest can help to identify, reject, or request retransmission of a corrupt PDU. This does not affect the running configuration or other sessions. To change the configuration permanently, use the storage iscsi header-digest command.
Use the no command option to disable this feature.
Example
Core_02 (config) # storage iscsi session header-digest enable
 
Core_02 (config) # failover-peer storage iscsi session header-digest enable
Product
SteelFusion Core
Related Commands
“edge id iscsi header-digest,” “show storage iscsi,” storage iscsi session data-digest enable