Configuring Administration Settings : Configuring maintenance settings : Upgrading your software
  
Upgrading your software
You can upgrade or revert to a backup version of the software in the Software Upgrade page. You can also enable and disable image signature verification, and view and upload image signing certificates. Image verification is enabled by default. We strongly recommend that it remain enabled at all times. Disable this feature only when absolutely necessary.
For more information about image signature verification, see Image signature verification.
The bottom of the page displays the software version history, including the version number and the software installation date.
To find allowed upgrades between RiOS versions and recommended upgrade paths, use the Software Upgrade tool on the Riverbed Support site at https://support.riverbed.com. The tool includes all of the recommended intermediate RiOS versions.
The SCC performs centrally managed software upgrades (immediate or scheduled) on any managed SteelHead. You can schedule upgrades to run immediately or schedule them during early morning maintenance windows, including the ability to schedule appliances reboots separately.
To enable image signature verification
Note: We strongly recommend this feature remain enabled at times.
1. Choose Administration > Maintenance: Software Upgrade to display the Software Upgrade page.
2. Select Image Signature Verification and click Apply.
To disable image signature verification
Note: Disable this feature only when absolutely necessary.
1. Choose Administration > Maintenance: Software Upgrade to display the Software Upgrade page.
2. Deselect Image Signature Verification and click Apply.
To add an image signing certificate
1. Choose Administration > Maintenance: Software Upgrade to display the Software Upgrade page.
2. Expand the Image Signing Certificate section.
3. Select Import.
4. Select a how you want to import your certificate.
–  Upload - This method supports uploading certificates in PKCS-12, DER, and PEM formats.
–  Paste it here - This method supports only certificates in PEM format.
5. Click Import Image Signing Certificate.
A dialog box appears and displays a warning that the existing certificate will be replaced by the one you are importing.
6. Click Import.
To view the details of an image signing certificate
1. Choose Administration > Maintenance: Software Upgrade to display the Software Upgrade page.
2. Expand the Image Signing Certificate section.
3. Select Details.
To revert the RiOS software version
1. Choose Administration > Maintenance: Software Upgrade to display the Software Upgrade page.
2. Under Software Upgrade, complete the configuration as described in this table.
Control
Description
Switch to Backup Version
Switches to the backup version on the next reboot.
Cancel
Cancels the software version switch on the next reboot.
To upgrade or revert software versions
1. Choose Administration > Maintenance: Software Upgrade to display the Software Upgrade page.
2. Under Software Upgrade, click Switch to Backup Version.
The appliance will revert to the backup version of its RiOS software when restarted. The button label changes to Cancel Version Switch; clicking it will cancel the reversion.
To upgrade the RiOS software version
1. Download the software image from the Riverbed Support site to a location such as your desktop. Optionally, in RiOS 8.5 and later, you can download a delta image directly from the Riverbed Support site to the SCC. The downloaded image includes only the incremental changes. The smaller file size means a faster download and less load on the network. To download a delta image, skip to step 2.
2. Choose Administration > Maintenance: Software Upgrade to display the Software Upgrade page.
3. Under Install Upgrade, complete the configuration as described in this table.
Control
Description
From URL
Select this option and specify the URL.
Use one of these formats:
http://host/path/to/file
https://host/path/to/file
ftp://user:password@host/path/to/file
scp://user:password@host/path/to/file
From Riverbed Support Site
Click this option and select the target release number from the drop-down list. The system uploads and installs the new image immediately after you click Install. To upload and install the image later, schedule another date or time before you click Install.
From Local File
Select this option and specify the path, or click Browse to go to the local file directory.
If you specify a file to upload in the Local File text box, the image is uploaded immediately; however the image is installed and the system is rebooted at the time you specify.
Schedule Upgrade for Later
Schedules the upgrade process. Specify the date and time to run the upgrade: yyyy/mm/dd hh:mm:ss
Install
Click to install the software upgrade on your system, unless you schedule it for later.
The software image can be quite large; uploading the image to the appliance and installing it can take a few minutes. Downloading a delta image directly from the Riverbed Support site is faster because the downloaded image includes only the incremental changes.
As the upgrade progresses, status messages appear.
After the installation is complete, the system reminds you to reboot the appliance to switch to the new version of the software.
Cancel
Cancels your changes.
4. Choose Administration: Maintenance > Reboot/Shut Down and click Reboot.
The appliance can take a few minutes to reboot. This is normal behavior as the software is configuring the recovery flash device. Don’t press Ctrl+C, unplug, or otherwise shut down the system during this first boot. There is no indication displayed during the system boot that the recovery flash device is being configured.
After the reboot, the Dashboard, Software Upgrade, and Support pages of the Management Console display the RiOS version upgrade.
Related topic
•  Displaying scheduled jobs