SteelFusion™ Command-Line Interface Reference Manual
Welcome
About this guide
Audience
Document conventions
Documentation and release notes
Contacting Riverbed
Using the Command-Line Interface
Connecting to the CLI
Overview of the CLI
Entering commands
Accessing online help
Error messages
Command negation
Running the configuration wizard
Saving configuration changes
User Mode Commands
CLI cross-product support
Displaying SteelFusion Core information
show device-failover (Core)
show edge
show stats storage dr-bytes-synced
show stats storage dr-disk-journal
show stats storage dr-fsync-bytes
show stats storage dr-latency
show stats storage dr-mem-journal
show stats storage dr-resync-bytes
show stats storage edge-bytes
show stats storage edge-stats
show stats storage filer-bytes
show stats storage filer-iops
show stats storage filer-latency
show stats storage lun-bytes
show stats storage lun-iops
show stats storage lun-latency
show stats storage network-bytes
show stats storage network-iops
show stats storage network-latency
show storage backup deleting-group all
show storage backup group
show storage backup policy
show storage backup proxy
show storage coredr edge
show storage coredr replica size-leeway
show storage coredr sec-site-luns
show storage coredr settings
show storage iscsi
show storage iscsi disc-portals portal
show storage iscsi mpio interfaces
show storage iscsi mpio-paths
show storage lun
show storage luns
show storage lun-global settings
show storage server
show storage snapshot
show storage snapshot policies
Displaying hypervisor information
show hypervisor hardware all
show hypervisor hardware error-log
show hypervisor hardware licensing
show hypervisor hardware memory-error
show hypervisor hardware temperature
show hypervisor image
show hypervisor images
show hypervisor image-fetch job
show hypervisor install-config
show hypervisor install-config network
show hypervisor install-config storage
show hypervisor installed
show hypervisor install notifications
show hypervisor license
show hypervisor log
show hypervisor network
show hypervisor support-matrix
show hypervisor usage
show hypervisor version
show hypervisor version-history
show virtualization
show hypervisor vm
Displaying Storage Information
show device-failover (Edge)
show edge server discovered
show edge servers
show service storage
show stats storage core-io-bytes
show stats storage initiator-bytes
show stats storage initiator-iops
show stats storage initiator-ltncy
show stats storage lun-bytes
show stats storage lun-commit-rate
show stats storage lun-iops
show stats storage lun-latency
show stats storage rebuild-status
show storage blockstore
show storage core
show storage iscsi
show storage lun
show storage luns
Enable Mode Commands
configuration bulk export
configuration bulk import
reload
reset factory
show rbm user
show rbm users
Configuration Mode Commands
System commands
alarm clear
alarm clear-threshold
alarm enable (Core)
alarm enable (Edge)
alarm error-threshold
alarm rate-limit
alarms reset-all
rbm user (Core)
rbm user (Edge)
SteelFusion Core commands
device-failover activate
device-failover peer set (Core)
device-failover peer clear (Core)
device-failover peerip
edge add id
edge id blockstore enc-type
edge id blockstore uncommitted
edge id iscsi data-digest
edge id iscsi header-digest
edge id iscsi initiator add
edge id iscsi initiator modify
edge id iscsi initiator remove
edge id iscsi initiator-group
edge id iscsi initiator-group modify
edge id iscsi target modify-name
edge id iscsi target security-only
edge id prepop schedule add
edge id prepop schedule modify
edge id prepop schedule remove
edge id virtual-ip
edge modify id branch-recovery clear
edge modify id clear-serial
edge modify id netdisk-mpio active-active enable
edge modify id serialize-snap enable
edge modify preferred-if
edge remove id
storage backup group add
storage backup group modify
storage backup group remove
storage backup policy add
storage backup policy modify
storage backup policy remove
storage backup proxy add
storage backup proxy modify
storage backup proxy remove
storage server add
storage server modify
storage server remove
storage block-disk
storage block-disk rescan
storage block-disk scan enable
storage coredr clear
storage coredr clear-params
storage coredr edge
storage coredr failover
storage coredr interface
storage coredr lun remove-replica
storage coredr lun replicate-to
storage coredr replication resume
storage coredr replication suspend
storage coredr set-params
storage coredr setup peer
storage coredr witness set
storage iscsi array-settings
storage iscsi array-settings modify
storage iscsi chap add
storage iscsi chap delete
storage iscsi chap modify
storage iscsi chap username
storage iscsi data-digest
storage iscsi header-digest
storage iscsi initiator modify auth mutual-chap
storage iscsi initiator modify name
storage iscsi mpio interface add
storage iscsi mpio interface remove name
storage iscsi portal add host
storage iscsi portal host disc-portal add
storage iscsi portal host disc-portal modify
storage iscsi portal host disc-portal remove
storage iscsi portal host offline-luns
storage iscsi portal host rescan-luns
storage iscsi portal host rescan-portals
storage iscsi portal host rescan-targets
storage iscsi portal host target add
storage iscsi portal host target modify
storage iscsi portal host target offline-luns
storage iscsi portal host target remove
storage iscsi portal modify host alias
storage iscsi portal modify host auth
storage iscsi portal modify host port
storage iscsi portal remove by-alias
storage iscsi portal remove host
storage iscsi report-naa-id enable
storage iscsi session data-digest enable
storage iscsi session header-digest enable
storage iscsi session immediate-data enable
storage iscsi session initial-r2t enable
storage iscsi session mpio
storage iscsi session mpio standard-routes
storage iscsi session scan-interval
storage iscsi session wait-interval
storage iscsi session write-balance enable
storage lun add block-disk
storage lun add edge-local
storage lun add iscsi
storage lun clear-pxy-state
storage lun modify accelerate-iops enable
storage lun modify auth-igroup
storage lun modify auth-initiator
storage lun modify branch-recovery
storage lun modify branch-recovery enable
storage lun modify branch-recovery restart
storage lun modify branch-recovery schedule
storage lun modify client-type
storage lun modify failover
storage lun modify map edge-id
storage lun modify mpio path
storage lun modify mpio policy
storage lun modify new-alias
storage lun modify offline
storage lun modify online
storage lun modify pinned
storage lun modify prepop
storage lun modify prepop schedule add
storage lun modify prepop schedule modify-sched
storage lun modify prepop schedule remove
storage lun modify prepop smart
storage lun modify prepop start-now
storage lun modify pri-snap
storage lun modify scheduled-snaps
storage lun modify scheduled-snaps add
storage lun modify scheduled-snaps remove
storage lun modify scsi-res
storage lun modify serialize-write enable
storage lun modify snapshot-config clear-host
storage lun modify snapshot-config app-consistent
storage lun modify snapshot-config proxy-backup
storage lun modify snapshot-config handoff enable
storage lun modify snapshot host
storage lun modify storage-group
storage lun modify unmap
storage lun modify-all scsi-res
storage lun remove
storage lun resize
storage lun setup-pxy-state
storage snapshot br-proxy-host
storage snapshot br-proxy-host remove host
storage snapshot handoff-host
storage snapshot handoff-host remove host
storage snapshot storage-array
storage snapshot storage-array remove host
storage snapshot storage-array modify host redundant-paths add rp-host
storagesnapshot storage-array modify host redundant-paths remove rp-host
storage snapshot storage-array remove host
storage snapshot skip_vm_reg_op enable
storage snapshot policy add
storage snapshot policy modify add-daily
storage snapshot policy modify add-hourly
storage snapshot policy modify add-weekly
storage snapshot policy remove
storage snapshot policy rename
storage snapshot test handoff delete serial
storage snapshot test handoff hello serial
storage snapshot test handoff take serial
storage snapshot test integrated delete serial
storage snapshot test integrated delete type
storage snapshot test integrated expose serial
storage snapshot test integrated expose type
storage snapshot test integrated proxy-backup serial
storage snapshot test integrated take serial
storage snapshot test integrated take type
storage snapshot test integrated un-expose serial
storage snapshot test integrated un-expose type
SteelFusion Edge commands
Hypervisor commands
clear hypervisor hardware error-log
hypervisor check upgrades
hypervisor console
hypervisor image delete
hypervisor image rename
hypervisor image-fetch
hypervisor initialize
hypervisor install
hypervisor install-config hostname
hypervisor install-config license key
hypervisor install-config network dns
hypervisor install-config network nic
hypervisor install-config network route ipv4
hypervisor install-config network route ipv6
hypervisor install-config network use-auto-config
hypervisor install-config network vswitch uplink
hypervisor install-config network vswitch vm-port
hypervisor install-config network vswitch vmk-port ipv4-dhcp
hypervisor install-config network vswitch vmk-port ipv4-ip
hypervisor install-config network vswitch vmk-port ipv6-dhcp
hypervisor install-config network vswitch vmk-port ipv6-ip
hypervisor install-config network vswitch vmk-port ipv6-router-adv
hypervisor install-config ntp enable
hypervisor install-config storage core-managed
hypervisor install-config storage direct-attached delete-existing
hypervisor install-config storage direct-attached lun
hypervisor license restore
hypervisor password
hypervisor reinstall
hypervisor restart
hypervisor upgrade
Storage commands
device-failover peer clear (Edge)
device-failover peer set (Edge)
storage backup trigger
storage core add host
storage core host local-interface
storage core host modify
storage core remove
storage iscsi mpio interface (Edge)
storage lun activate
storage lun snapshot create
storage lun snapshot remove
storage lun snapshot remove non-replicated
SteelFusion Ports
SteelFusion ports
Index
SteelFusion™ Command-Line Interface Reference Manual
Index